beautypg.com

Henny Penny BCM-110 User Manual

Page 7

background image

Model BCF-24/65/110, BCM-110

1-3. TROUBLESHOOTING
(Continued)

Problem

Cause

Correction

Slow to decrease

Condenser obstructed by dirt

Clean the condenser

in temperature (decline in
performance)

Evaporator iced up

Perform a De-icing Cycle

Refrigerating problem

Check refrigeration circuit and
components

Display temperature does

In Frigiprobe Mode, the display

Normal

not match the actual inlet air

shows the product temperature

temperature (No alarm)

In timer mode, or hold mode,

Ohm out the probe and check

the probe may be showing the

the reading with the table located

wrong temperature

in this section; change the probe
if it is out of tolerance

Green compressor indicator

Compressor and condenser fan

light on and the compressor

do not work:

not working, or working

- Faulty contactor

Check contactor and change if

sometimes

necessary

- Faulty control board relay-no

Replace control board

voltage across terminals 10-11

Compressor works, but condenser
fan does not:
- Faulty condenser fan

Replace fan

Compressor and condenser fan
work together:
- Faulty protection component

Check items and replace if

for the compressor (overload

necessary

protector, potential relay, start
and run capacitor)

- Faulty overload protector of

Check fan and replace if

condenser fan

necessary

603

1-3