ELECTRICAL CONNECTION TO JUNCTION BOX

If local codes permit connecting the cabinet-grounding

conductor to the neutral (white) wire in the junction box:

1

Disconnect the power supply.

2

Remove the junction box cover.

3

Connect the oven cable to the junction box through
the U.L. listed conduit connector.

4

Connect the two black wires together with
twist-on connectors.

5

Connect the two red wires together with twist-on
connectors.

6

Connect electrical connection according to local
codes and ordinances.

7

Connect the factory-taped green and white oven cable
wires to the neutral (white) wire in the junction box.

8

Replace the junction box cover.

Four-wire electrical system

1

Disconnect the power supply.

2

Remove the junction box cover.

3

Connect the oven cable to the junction box through the U.L.-listed conduit connector.

4

Connect the two black wires together with twist-on connectors.

5

Connect the two red wires together with twist-on connectors.

6

Connect electrical connection according to local codes and ordinances.

7

Separate the green and white oven cable wires.

8

Connect the white oven cable wire to the neutral (white) wire in junction box.

9

Connect the green grounding oven cable wire to the (green) grounding wire in the junction box.
Do not connect the green grounding wire to the neutral (white) wire in junction box.

!0

Replace the junction box cover.

If local codes DO NOT PERMIT connecting the cabinet-grounding

conductor to the neutral (white) wire in junction box:

1

Disconnect the power supply.

2

Remove the junction box cover.

3

Connect the oven cable to the junction box through the U.L.-
listed conduit connector.

4

Connect the two black wires together with twist-on connectors.

5

Connect the two red wires together with twist-on connectors.

6

Connect electrical connection according to local codes and
ordinances.

7

Separate the factory-taped green and white oven cable wires.

8

Connect the white oven cable wire to the neutral (white) wire
in junction box.

9

Connect the green grounding oven cable wire to a grounded
wire in the junction box.

!0

Replace the junction box cover.

Connection methods

MODEL

VOLTAGE

MAX CURRENT
DRAW

MAX LOAD

OB30 Single

208 V

16.6 A

3.5 kW

240 V

19.4 A

4.6 kW

OB30 Double

208 V

33.2 A

7.0 kW

240 V

38.3 A

9.2 kW

a

B

cable from

power supply

Junction box locations

junction box

location for

undercounter

installation

junction box

location for

wall installation

cable from

power supply

box

black

wires

black

wires

red

wires

red

wires

green grounding

oven wires –

factory taped

white

wires

white and

green grounding

oven wires –

factory taped

U.L.-listed

conduit

connector

U.L.-listed

conduit

connector

Nameplate location

box