SECURE THE OVEN TO THE CABINETRY

Oven may vary

1

Position the oven in the prepared cavity.

IMPORTANT!

Do not lift the oven by the door handle.

2

Open the oven door fully.

3

Mark and pre-drill the screw holes.

4

Use the supplied screws to secure the oven to the cabinetry.

IMPORTANT!

Do not over-tighten the screws.

Do not seal the oven into the cabinetry with silicone or glue. This makes
future servicing difficult. Fisher & Paykel will not cover the costs of
removing the oven, or of damage caused by this removal.

8

ELECTRICAL CONNECTION TO JUNCTION BOX

Junction box

location for:

undercounter

installation

Junction box

location for:

wall installation

All models

Voltage Max. current Max.

draw load

208V 16.6 A 3.5 kW
240V

19.4 A 4.6 kW

1

Disconnect the power supply.

2

Remove the junction box cover.

3

Connect the oven cable to the junction

box through the U.L.-listed conduit
connector.

4

Connect the two black wires together

with twist-on connectors.

5

Connect the two red wires together with

twist-on connectors.

6

Connect electrical connection according

to local codes and ordinances.

If local codes permit connecting the
cabinet-grounding conductor to the neutral
white wire in the junction box:

7A

Connect the factory-taped green and white

oven cable wires to the neutral (white) wire
in the junction box.

8A

Replace the junction box cover.

OR If local codes DO NOT PERMIT
connecting the cabinet-grounding
conductor to the neutral (white) wire in
junction box:

7B

Separate the factory-taped green and

white oven cable wires.

8B

Connect the white oven cable wire to

the neutral (white) wire in junction box.

9B

Connect the green grounding oven cable

wire to a grounded wire in the junction
box.

!0B

Replace the junction box cover.

OR If connecting to a four-wire electrical
system:

7C

Separate the green and white oven cable

wires.

8C

Connect the white oven cable wire to the

neutral (white) wire in junction box.

9C

Connect the green grounding oven cable

wire to the (green) grounding wire in the
junction box.

Do not connect the green grounding wire to
the neutral (white) wire in junction box.

!0C

Replace the junction box cover.

Nameplate

cable from
power supply

black
wires

UL - listed
conduit connector

box

red wires

white and green
grounding oven
wires - factory
taped

UL - listed
conduit connector

box

cable from
power supply

white
wires

red wires

green grounding
oven wires
- factory taped

black