Page 11: Other protections

background image

- 22 -

Using the Wide Panel

Pull out the wide panel and place it
over the flash head as shown. The
flash coverage will then be extended
to 14 mm.

The catchlight panel will come out
at the same time. Push the
catchlight panel back in.

Low Battery Warning

If the battery power is low, <

> will

appear and blink on the LCD panel.
P l e a s e r e p l a c e t h e b a t t e r y
immediately. When the low battery
indicator is displayed, the ZOOM can
not be adjusted, it will constantly be
24mm.

C.Fn: Setting Custom Functions

The following table lists the available and unavailable custom
functions of this flash.

ST

AF

BL

ON

OF

ON

OF

10 sec.

OF

ON

Auto sleep

(standby)

AF-assist beam

Backlighting

control

C

.

Fn

Custom

Functions

Custom Function
Signs

Function

Setting No

.

Settings & Description

ON

OFF

ON

OFF

Off in 10 sec.

Always off

Always lighting

1

.

Press the <

ZOOM

> Button for 2 seconds until C.Fn menu is

displayed.

2

.

Turn the Select Dial to select the Custom Functions.

3

.

Press the <

SET

> Button and the Setting No. blinks.

4. Turn the Select Dial to set the desired number. Pressing the

<

SET

> Button will confirm the settings.

5

.

Press the <

ZOOM

> Button to exit.

Protection Function

1. Over-Temperature Protection

To avoid overheating and deteriorating the flash head, do not fire

more than 30 continuous flashes in fast succession at 1/1 full
power. After 30 continuous flashes, allow a rest time of at least 10
minutes.

If you fire more than 30 continuous flashes and then fire more

flashes in short intervals, the inner over-temperature protection
function may be activated and make the recycling time over 10
seconds. If this occurs, allow a rest time of about 10 minutes, and
the flash unit will then return to normal.

When the over-temperature protection is started, is shown on

the LCD display.

Number of flashes that will activate over-temperature protection:

Number of flashes that will activate over-temperature protection in
high-speed sync triggering mode:

Power Output Level

1/1

1/2 +0.7

1/2 +0.3

1/2

1/4(+0.3,+0.7)

1/8(+0.3,+0.7)

1/16(+0.3,+0.7)

1/32(+0.3,+0.7)

1/64(+0.3,+0.7)

1/128(+0.3,+0.7)

Number of Flashes

30

40

50

60

100

200

300

500

1000

Power Output

1/1

1/2(+0.3,+0.7);

1/4(+0.3,+0.7)

1/8(+0.3,+0.7);

1/16(+0.3,+0.7)

Times

15

20

30

40

Meaning

A failure occurs on the recycling system so that the
flash cannot fire.
Please restart the flash unit. If the problem still exists,
please send this product to a maintenance center.
The voltage on two outlets of the flash tube is too high.
Please send this product to a maintenance center.
There are some errors occurred during the upgrading
process. Please using the correct firmware upgrade
method.

Prompts on LCD Panel

E1

E3

E9

2. Other Protections

The system provides real-time protection to secure the device and
your safety. The following lists prompts for your reference:

- 43 -

- 44 -

When pull out the wide panel, the ZOOM will constantly be
14mm. The button will not work.