Power Management

NOTE: After use, slide the power switch to OFF position.

1.

Switch to the ON, the flash will start charging (the charging indicator is

dim). After several seconds, the charging indicator turns red and the
macro ring flash is ready to shoot. For a test flash, press the test button.
After use, slide the power switch to OFF position to power off.

2.

If the red charging indicator lamp flickers in every 1s, it indicates low

battery. In such case, the power will turn off automatically and you need
to replace the batteries.

Output Control

The flash unit has 5 steps of power output control which indicated by 5
pieces of LED lamp for different level. Press “+” to make power higher
and they are 1/16, 1/8, 1/4, 1/2, 1/1, otherwise, press “-” to make power
lower.

Synchronization Function

The ring flash and camera will trigger synchronously by using a PC sync
cord to connect the sync terminals of the camera and the ring flash
together.

Power Saving Function

The flash unit is equipped with power saving mode. When idle for about
30 minutes, it will enter “deeper sleep” state automatically to save power.
In this case, the charging indicator flicks every 3 seconds. To restart the
unit, just press any button.

Protection Function

1.

Protection in Continuous Flashes

To prevent the flash head from getting too hot and damage, please do
not flash over 50 times when in power level 1/2, 1/1. Please cool down
the flash unit for at least 10 minutes. The over-temperature protection
function will be activated if you continue to flash after 50 times. In this
case, the charging time will turn to 10-25s. Please cool down the flash
unit around 10 minutes and it will turn to normal state.

USING RING FLASH

Power Output

Flashes

Approx.

Number of flashes that will activate over-temperature protection:

1/1

,

1/2

50

1/4

,

1/8

100

1/16

200

2.

Systematic Over-temperature Protection

When the inner circuit is over-heating, which indicates over use of the
flash unit, the inner circuit will shut down power automatically. The flash
unit will turn to normal state after the inner circuit is cooled down (about
10 minutes).

Name

Guide Number

Power

Flash Times

Recycle Time

Color Temperature

Flash Duration

Dimension

Net Weight

Specifications

SPECIFICATIONS

Packaging Includes:
Ring Flash…(1)
Instruction Manual…(1)
Adapter Rings

49mm,52mm,55mm,58mm,62mm and 67mm

Power Pack for Speedlite.

To provide power supply for
speedlite, shorten the recycle
time, up to 300~1000 flashes
at full power.

Power Flash Connecting Cable.

Cx(Canon), Nx(Nikon), Sx(Sony),
Mx(Metz)
To connect the speedlite and power
pack, dedicated cable available for
different speedlite.

OPTIONAL ACCESSORIES

10(m ISO 100)

4x AA batteries(Alkaline or Ni-MH are usable)

300-1000 times(AA alkaline batteries used)

Approx. 0.1~2S(AA alkaline batteries used)

5600K+200K

370g

Ring Flash Head 128*103*28 mm

Control Unit 75*50*160 mm

1/300S-1/5000S