beautypg.com

High-speed sync – Godox QT400IIM Flash Head User Manual

Page 6

background image

mask

sec

to

.

1

speed

M

CH

S

%

- 23 -

- 24 -

Stable Color Temperature Mode and High-Speed Flash (speed) Mode

Stable Color Temperature Mode or High-Speed Flash (speed) Mode can be chosen in the C.Fn-F1 setting. These

two modes are effective in M/Multi mode and ineffective in high-speed sync mode.

Stable Color Temperature Mode

: color temperature ranges within ±200K, which is a good choice for the

photographers who pursues stable color temperature.

High-Speed Flash (speed) Mode

: the max flash duration is up to t0.1=1/28984, which is perfect for capturing the

fast-changing actions. As the color temperature is a little higher in this mode, please set the camera’s white balance

parameter to the proportional color temperature amount (see the chart below) or AWB (Auto White Balance).

1/128

5729

1/ 4246

1/128

9335

1/ 28984

1/128+0.3

5718

1/ 4166

1/128+0.3

9108

1/ 26666

1/128+0.7

5686

1/ 3920

1/128+0.7

9010

1/ 24690

1/64

5619

1/ 3920

1/64

8535

1/ 22988

1/64+0.3

5635

1/ 3920

1/64+0.3

8205

1/ 20832

1/64+0.7

5657

1/ 3920

1/64+0.7

7698

1/ 18518

1/32

5630

1/ 3920

1/32

7367

1/ 16666

1/32+0.3

5639

1/ 3920

1/32+0.3

7151

1/ 15150

1/32+0.7

5608

1/ 3702

1/32+0.7

6856

1/ 13332

1/16

5620

1/ 3702

1/16

6579

1/ 11904

1/16+0.3

5647

1/ 3702

1/16+0.3

6440

1/ 10582

1/16+0.7

5657

1/ 3702

1/16+0.7

6216

1/ 8888

1/8

5677

1/ 3702

1/8

6126

1/ 7662

1/8+0.3

5674

1/ 3508

1/8+0.3

6072

1/ 6666

1/8+0.7

5610

1/ 2666

1/8+0.7

5954

1/ 5332

1/4

5568

1/ 2298

1/4

5907

1/ 4596

1/4+0.3

5566

1/ 1904

1/4+0.3

5867

1/ 3808

1/4+0.7

5656

1/ 1626

1/4+0.7

5837

1/ 2898

1/2

5646

1/ 1332

1/2

5844

1/ 2222

1/2+0.3

5681

1/ 1256

1/2+0.3

5738

1/ 1550

1/2+0.7

5649

1/ 832

1/2+0.7

5636

1/ 832

1/1

5549

1/ 316

1/1

5539

1/ 316

SEKONIC C-700

t0.1(S)

t0.1(S)

220V QT600IIM Prototype Test

Test Environment

Darkroom

Color Temperature
Test

Equipment

Testing Method

Trigger beyond 2 meters and average the amount of 3 tests.

Flash Duration
(t0.1)

IGBT control the time of turning on the flash

Stable Color Temperature Mode

High-Speed Flash (speed) Mode

CCT(K)

Level

Parameter

Color

Temperature

Flash Duration

Level

CCT(K)

Parameter

Color

Temperature

Flash Duration

SEKONIC C-700

t0.1(S)

t0.1(S)

1/128

5744

1/ 4938

1/128

9323

1/ 35086

1/128+0.3

5759

1/ 4694

1/128+0.3

9277

1/ 33332

1/128+0.7

5747

1/ 4444

1/128+0.7

9130

1/ 30302

1/64

5761

1/ 4444

1/64

8919

1/ 27776

1/64+0.3

5775

1/ 4444

1/64+0.3

8926

1/ 25640

1/64+0.7

5780

1/ 4444

1/64+0.7

8836

1/ 22222

1/32

5753

1/ 4444

1/32

8432

1/ 20202

1/32+0.3

5771

1/ 4444

1/32+0.3

8183

1/ 18518

1/32+0.7

5754

1/ 4444

1/32+0.7

7784

1/ 16666

1/16

5764

1/ 4444

1/16

7368

1/ 15150

1/16+0.3

5752

1/ 4444

1/16+0.3

6983

1/ 13332

1/16+0.7

5755

1/ 4444

1/16+0.7

6763

1/ 11494

1/8

5777

1/ 4444

1/8

6533

1/ 10100

1/8+0.3

5734

1/ 3920

1/8+0.3

6377

1/ 8546

1/8+0.7

5665

1/ 3030

1/8+0.7

6192

1/ 6872

1/4

5604

1/ 2468

1/4

6061

1/ 5648

1/4+0.3

5621

1/ 2468

1/4+0.3

5957

1/ 4566

1/4+0.7

5626

1/ 2222

1/4+0.7

5840

1/ 3508

1/2

5654

1/ 2082

1/2

5962

1/ 2656

1/2+0.3

5672

1/ 1514

1/2+0.3

5807

1/ 2014

1/2+0.7

5695

1/ 1148

1/2+0.7

5711

1/ 1148

1/1

5595

1/ 416

1/1

5579

1/ 416

In this mode, you can set the flash output from 1/1 full power to 1/16th power in 0.3 stop increments.

High Speed Sync enables the flash to synchronize with all camera shutter speeds. This is convenient when you

want to use aperture priority for fill-flash portraits.

Turn the Select Dial to set the

2

flash output power.

Press the <

MODE

> Button

1

so that < > is displayed.

High-Speed Sync

Please use the transmitter of

3

X1 series.

220V QT400IIM Prototype Test

Test Environment

Darkroom

Color Temperature
Test

Equipment

Testing Method

Trigger beyond 2 meters and average the amount of 3 tests.

Flash Duration
(t0.1)

IGBT control the time of turning on the flash

Stable Color Temperature Mode

High-Speed Flash (speed) Mode

CCT(K)

Level

Parameter

Color

Temperature

Flash Duration

Level

CCT(K)

Parameter

Color

Temperature

Flash Duration

MOD/OFF

mask

to

.

1

M

CH

S

%