Fluidyne Control Systems 6622 Series Fuel Consumption Monitor User Manual
Series 6622 : fuel consumption monitor, Specifications, Design features
Fluidyne Control Systems (P) Ltd.
S. No. 79/2,Plot No.12, Near Agarwal Godown, Shivne,
Pune-411 023. India
Tel.: 020-25290504, 25290870 Fax: 020-25292773
E-mail: [email protected]
Series 6622 : Fuel Consumption Monitor
For Cummins Engines / Gensets with PT Fuel System
Models NT / NTA / KT / KTA / VTA / KV
www.fluidyne.co.in
Flow Range
Accuracy
Service
Operating Temperature
Display
Filter Element
Power Supply
Mounting
Pressure Drop
Engine Run Time
Switch
Specifications
Accuracy guaranteed over 12-500 LPH flow range
Measures net fuel consumption
Ensures return fuel deareation for Cummins PT system
HSD,LDO compatible
Gravity head not required for operation
24 V DC powered
Built it in filter
Design Features
·
·
·
·
·
·
The Fuel Consumption Monitor is compact fuel flow
measuring system specially designed to suit Cummins
Engines with PT Fuel System for monitoring the net fuel
consumption of stationary equipment like engines,
gensets, pumpsets, compressors etc. After accounting for
the return fuel from the engine. The unit is provided with a
24V DC powered Flow Indicator which ensures accuracy
with a variety of fuels under all operating conditions.
Introduction
Dimensions
12 - 500 LPH
± 0.5% of reading
HSD / LDO
0 - 70 ºC
8 digit dot matrix LCD
Fuel Totaliser : 999999.9 Ltrs.
Engine Run Time : 9999.99 Hrs.
25 Micron Replaceable
12V DC from cranking battery
MS fabricated frame for ground mounting of
unit
<1” of Hg at 500 LPH on Diesel Service
Mounting : On Oil Gallery
·
Inlet From
3/4" BSPF
Tank
361
Return From
1/2" BSPF
Engine
237
3/4" BSPF
To Engine
Outlet
5
5
3
:
:
:
:
:
:
:
:
:
:
Installation
Fuel Inlet
Line
Storage Tank
G/L
Water
Separator
Injector
Fuel Pump Return
Oil Filter
Engine Run Time Switch
Return
Suction
Filter
Suction Hose
Engine
24V DC
Battery
+
-