Series 6622 : Fuel Consumption Monitor

For Cummins Engines / Gensets with PT Fuel System
Models NT / NTA / KT / KTA / VTA / KV

www.fluidyne.co.in

Flow Range
Accuracy
Service
Operating Temperature
Display

Filter Element
Power Supply
Mounting

Pressure Drop
Engine Run Time
Switch

Specifications

Accuracy guaranteed over 12-500 LPH flow range
Measures net fuel consumption
Ensures return fuel deareation for Cummins PT system
HSD,LDO compatible
Gravity head not required for operation
24 V DC powered
Built it in filter

Design Features

·

·
·

·
·
·

The Fuel Consumption Monitor is compact fuel flow
measuring system specially designed to suit Cummins
Engines with PT Fuel System for monitoring the net fuel
consumption of stationary equipment like engines,
gensets, pumpsets, compressors etc. After accounting for
the return fuel from the engine. The unit is provided with a
24V DC powered Flow Indicator which ensures accuracy
with a variety of fuels under all operating conditions.

Introduction

Dimensions

12 - 500 LPH
± 0.5% of reading
HSD / LDO
0 - 70 ºC
8 digit dot matrix LCD
Fuel Totaliser : 999999.9 Ltrs.
Engine Run Time : 9999.99 Hrs.
25 Micron Replaceable
12V DC from cranking battery
MS fabricated frame for ground mounting of
unit
<1” of Hg at 500 LPH on Diesel Service
Mounting : On Oil Gallery

·

Inlet From

3/4" BSPF

Tank

361

Return From

1/2" BSPF

Engine

237

3/4" BSPF

To Engine

Outlet

5

5

3

:
:
:
:
:

:
:
:

:
:

Installation

Fuel Inlet

Line

Storage Tank

G/L

Water
Separator

Injector

Fuel Pump Return

Oil Filter

Engine Run Time Switch

Return

Suction
Filter

Suction Hose

Engine

24V DC
Battery

+

-