beautypg.com

Charge115, Fig.2 – Sealey CHARGE106 User Manual

Page 3

background image

4. MULtIPLe battery chargINg

5. FUSe & therMaL PrOtectION

5.1. Your charger is equipped with two front panel mounted fuses. the output protection

fuse on the left will interrupt the circuit in the following circumstances:

a) overload: too high a current to the battery.

b) short circuit: clamps touch, or the polarity on battery is reversed.

If the output fuse blows take the following action:

5.1.1. Disconnect the charger from the mains power supply.

5.1.2. Allow the unit to cool down, establish the reason for fuse blowing and correct.

5.1.3. replace the fuse using only a sealey replacement fuse.

5.2. the input protection fuse is situated to the right hand side of the control panel. If this fuse blows, replace only with a sealey fuse of the

same value.

5.3. thermal Protection. When a high current causes the charger to overheat the internal thermal protection will cut off the

current. When the charger has cooled sufficiently it will automatically reconnect.

4.1. A number of batteries may be charged at the same time. to do so we recommend

“parallel connection” as shown in fig.2A

4.2. two 12 volt batteries may be charged in series using the 24 volt output as shown in

fig.2B. this is only recommended if both batteries are of similar capacity and

are in a similar state of discharge.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPOrtaNt: no liability is accepted for incorrect use of this product.

WarraNty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFOrMatION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey group,

Kempson Way, suffolk Business Park

,

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

cHArGE106,107,110,112,115,124 Issue: 1 - 16/04/12

WarNINg! the charger will not switch off automatically. the state of charge should be regularly monitored by the person with

resposibility for charging the battery. Do not leave the charger operating unattended or overnight.

3.3.5. unplug the charger from the mains power supply and

then disconnect the clamps from the battery terminals. clean and store the

charger in a safe, dry area.

3.3.6. replace the battery electrolyte cover or caps. Wipe up any splashes or spillages, remembering that the electrolyte is a corrosive acid.

return the battery to the vehicle, secure according the manufacturer’s instructions and re-connect the power leads. check to ensure

that all tools are removed before closing the bonnet or boot.

3.4. WarNINg! LOW MaINteNaNce or SeaLeD “NO MaINteNaNce” battery chargINg

3.4.1. A low, or no maintenance battery, must be charged slowly.

DO NOt use the 'Boost' setting. continually monitor the voltage across the

battery terminals and when it reaches 14.4 volts, stop charging.

charge106

charge110

charge124

fig.2

Parts support is available for these product. to obtain a parts listing and/or diagram, please log on to

www.sealey.co.uk, email [email protected] or phone 01284 757500.

charge115