10 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
10.1
Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
10.2
Lubrication
Turn the drill shaft to the maximum drilling depth once per 3 months and grease it slightly
with oil.
11 TECHNICAL DATA
POWX154
Mains voltage
230V
Mains frequency
50Hz
Power input
500W
No-load speed
425-2545 min-1
Number of drilling speeds
12
Chuck capacity
1,5 - 16mm
Table dimensions
200 x 200 mm
With extensions
240(330)x200mm
Pillar height
850mm
Weight
35,2 kg
Cross laser
yes
12 NOISE
Noise values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
65 dB(A)
Acoustic power level LwA
78 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
13 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by a
qualified person (qualified electrician).