Problem

Possible Cause

Possible Solution

Power Indicator
will not illuminate
(blue)

No power to the
control panel

Inspect the 110 volt GFCI outlet/12
volt AC transformer power outlet

Controller failure

Contact Dealer for repair/replacement

Ionization
Indicator is
flashing (green)

Debris lodged between
the electrodes

Remove the electrodes by rotating
½ turn in a counter clockwise direction.
Inspect the electrodes and remove
any debris

The electrodes are not
immersed in water

Check the water flow through the
electrode housing and verify that the
housing is full of water

Ionization
Indicator is
flashing (green)
while the display
reads ‘00’

Control panel cannot
detect a connection the
electrode

Inspect the quick-connect plug on the
Electrode and verify that the line to the
control panel is not damaged

Electrodes are depleted

Remove the electrodes by rotating
½ turn in a counter clockwise direction.
Inspect the electrodes and verify that
replacement is needed. Install a new
TRION2-RA replacement electrode.

Low copper level

Level of ionization set
too low

Increase the level of ionization and
monitor copper levels

Copper ions are quickly
consumed

It is not unusual for the test strips to
show low copper levels after long
periods of operating at “full” power.
This is due to copper ions being
consumed within the water feature as
they break down organics.

High copper level

Level of ionization set
too high

Reduce ionization to ‘01’ on the
display until test results are below
0.3 ppm. A partial water change will
also aid in reducing copper levels

8