31-DVIM33C

11

W A R N I N G

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved
with this appliance may result in property damage or personal injury.

Non–Combustible Zone

7”

16”

N O T E

If existing wood fireplace hearth protection is removed it must
be replaced by a non-combustible hearth protection 7” thick,
extending a minimum of 16” (406 mm) from the front of the
fireplace insert or have a minimum 7” (178 mm) clearance
below the level of the bottom of the insert.

C A U T I O N

This appliance is designed for use in any masonry or factory-built, wood-burning fireplace. It cannot
be enclosed by combustible material and used as a built-in gas fireplace.

W A R N I N G

Any hearth extending out in front of the insert must not
have any portion above 7” below the bottom of the unit
made from combustible materials. This includes any
type of framing underneath a non-combustible material
such as tile, marble or stone. Any material below 7” can
be combustible.

Fig 11-B

N O T E

All specified clearances must be maintained

from the top surface of carpeting, tile, etc.

N O T E

All specified clearances must be maintained

from the top surface of carpeting, tile, etc.

Non–Combustible Zone

7”

16”

Fig. 11-A