4. CABLE

SPECIFICATIONS

Model:

CERVITRONIC PAR-POS Code 04754502

Construction
Conductor: Annealed

electrolytic copper, tinned

As Norm:

UNE 21064

Isolator:

Poliolefina (PE - Solid)

Composition: By

pars

Par shield:

Tape Al/Pet + Drain CuSn.

Cover:

100 % Physical

All over shield:

Tape Al/Pet + Drain Cu Sn

Cover:

100 % Physical

Exterior cover:

PVC

Colour: Black

Electrical Characteristics
Working Voltage:

250 V.

Testing Voltage:

1.000 V. 1 minute/s.

Electrical resistance:

≤ 52,2 Ω/km

Capacity: C* / C**

90-170 pF/m

C* capacity between conductors

C** capacity between one conductor and the rest connected to the shields

Physical Characteristics
Exterior diameter:

6,6 mm

Bending radius:

66 mm

Working temperature:

-5... +70ºC

Fire risk : Does not propagate flame as per Norm : IEC 60332-1 y EN 50265
Section: 0,34

mm2

Weight:

51 kg/km

Cable section

1 PVC

cover

2 Exterior

shield

wire

3 Insulating

film

4

Pair 1/2 shield wire

5 PVC

insulation

6

Pair 1/2 conductor

7 Aluminium

shield