Super Systems AC20 User Manual

Page 88

background image

86

INPUTS

INPUTS

INPUTS

INPUTS

INPUTS

A)

A)

A)

A)

A) MAIN INPUT

MAIN INPUT

MAIN INPUT

MAIN INPUT

MAIN INPUT

T y p e :

T y p e :

T y p e :

T y p e :

T y p e :
- 0 to 1500 mV (when mV sensor output or oxygen are selected

as primary controlled variable).

- 1000 to 1300 mV (when carbon potential or dew point is

selected as primary controlled variable).
NOTE:

NOTE:

NOTE:

NOTE:

NOTE: if the probe input value is out of the 1000 to 1300 mV,
the range automatically becomes 0 to 1500 mV.

Input type

Input type

Input type

Input type

Input type: isolated from others measuring inputs and digital
inputs.

Carbon range:

Carbon range:

Carbon range:

Carbon range:

Carbon range: 0.00 to 2.00%
Dew point range:

Dew point range:

Dew point range:

Dew point range:

Dew point range: -100 to 100 °F or -75 to 40 °C

Oxygen range:

Oxygen range:

Oxygen range:

Oxygen range:

Oxygen range:

0.0 to 25.0 %

R e s o l u t i o n :

R e s o l u t i o n :

R e s o l u t i o n :

R e s o l u t i o n :

R e s o l u t i o n :

0.1

mV range:

mV range:

mV range:

mV range:

mV range: 0 to 1500 mV
Cargon resolution:

Cargon resolution:

Cargon resolution:

Cargon resolution:

Cargon resolution: 0.01%
Dew point resolution

Dew point resolution

Dew point resolution

Dew point resolution

Dew point resolution: 1°F (1°C)
mV resolution

mV resolution

mV resolution

mV resolution

mV resolution: 1 mV
A c c u r a c y :

A c c u r a c y :

A c c u r a c y :

A c c u r a c y :

A c c u r a c y :
+ 0.02 digits for 0.40 to 1.60 % of the carbon range.
+ 0.03 digits for the remaining carbon range.

Temperature drift:

Temperature drift:

Temperature drift:

Temperature drift:

Temperature drift:
- 350 ppm/°C when the range is 1000 to 1300 mV.
- 200 ppm/°C when the range is 0 to 1500 mV.
Input impedance

Input impedance

Input impedance

Input impedance

Input impedance: > 100 M

Sampling time:

Sampling time:

Sampling time:

Sampling time:

Sampling time: 125 ms (typical).
Display updating time

Display updating time

Display updating time

Display updating time

Display updating time: 375 ms.
Insulation voltage:

Insulation voltage:

Insulation voltage:

Insulation voltage:

Insulation voltage: 500 VAC
Probe resistance:

Probe resistance:

Probe resistance:

Probe resistance:

Probe resistance: up to 100 K

Accuracy on probe resistance measurement:

Accuracy on probe resistance measurement:

Accuracy on probe resistance measurement:

Accuracy on probe resistance measurement:

Accuracy on probe resistance measurement: 2% f.s.v.

B) TEMPERATURE INPUT

B) TEMPERATURE INPUT

B) TEMPERATURE INPUT

B) TEMPERATURE INPUT

B) TEMPERATURE INPUT
Thermocouple type:

Thermocouple type:

Thermocouple type:

Thermocouple type:

Thermocouple type: K, S, R, B
Input type

Input type

Input type

Input type

Input type: not isolated from others measuring inputs and
digital inputs.
Sampling time:

Sampling time:

Sampling time:

Sampling time:

Sampling time: 1125 ms if carbon monoxide/remote set point

input is used.

750 ms otherwise.

Accuracy

Accuracy

Accuracy

Accuracy

Accuracy: + 0.2% f.s.v. + 1 digit @ 25 °C and nominal power

supply voltage.

Temperature drift:

Temperature drift:

Temperature drift:

Temperature drift:

Temperature drift: < 200 ppm/°C of full span
Source impedance:

Source impedance:

Source impedance:

Source impedance:

Source impedance: 100

max.

Current for TC open detection:

Current for TC open detection:

Current for TC open detection:

Current for TC open detection:

Current for TC open detection: -100 nA.
Cold junction

Cold junction

Cold junction

Cold junction

Cold junction: automatic compensation from 0 to 50 °C.
Cold junction accuracy

Cold junction accuracy

Cold junction accuracy

Cold junction accuracy

Cold junction accuracy : 0.1 °C/°C