Owners manual 9 controls and connections – Dynaudio SUB 600 User Manual
Page 12

Owners Manual
9
Controls and connections
➐
SUB I/O, To Slave
• LFE/Slave IN: input for LFE signal from processor/receiver. Note that the signal
must be a true LFE signal or already have been filtered by the processor/receiver,
as SUB Lowpass does not have an effect in combination with the LFE input.
• OUT: output to next subwoofer if installed.
➑
LFE/Slave
Subwoofer operation mode LFE or Slave:
• LFE: setting if just one subwoofer is used or for first subwoofer if system consists
of multiple subwoofers. Note that the SUB Lowpass control does not have an
effect when the LFE Mode is selected.
• Slave: setting for second and all following subwoofers. Note that the SUB
Lowpass, PHASE and GAIN controls do not have an effect when the Slave
Mode is selected.
➒
ON/OFF
Main power switch (to switch the subwoofer manually on and off).
LED: shows operation mode:
• red = subwoofer switched on and in mute mode
• green = subwoofer is activated
➓
AC IN
Main power input.
ON
AUTO
GAIN
POWER
PHASE
SUB Lowpass
SAT Highpass
SAT/SUB Input
SAT Output
LFE / Slave IN
OUT
Flat 60 Hz
LFE
Slave
80 Hz
Min
Max
50 Hz
150 Hz
0° 180°
LEFT
RIGHT
SUB I/O
To Slave
100-120V/220-240V
~ 50/60Hz 3.15A
FUSE T3.15A L 250V
OFF
ON
➊
➋
➌
➍
➎
➏
➐
➑
➒
➓
1