Erd60, Planning guide, 60” wide, epicure™ range – Dacor ERD60 User Manual

Page 3

background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

5.9

60” wide,

Epicure™ range

ErD60

NOTES:

1. utilities may be located in the lower left corner of

the adjacent right cabinet. (Recommended)

2. Contact your local building department to verify

compliance with local code interpretation.

3. Two electrical circuits and gas supplies required.

"A"

18” (457mm) Min.

Both Sides

30" (762mm) Min. from finished countertop

to combustible/non-combustible surface

Recommended

Utility Location

10” (254mm) Min.

from edge of cooktop

to combustible side wall

above finished countertop

(both sides)

Model No.

“A” Minimum Hood Width

“A” Recommended Hood Width

ERD60

60” (1524mm)

66” (1676mm)

UPPEr CAbINET DImENsIoNs

(Upper Cabinets 13” (330mm) Maximum Depth)

Model No.

Dedicated Circuit

Required

Total

Connected Load

Approximate

Shipping

Weight

ERD60

240VAC, 4-wire,

60Hz, 30A

(Breaker)

4.1kW (21A)

730 lbs.

(Two Dedicated Circuits required)

3/3