Gas connection – Permasteel PG-50601SRL(N) User Manual
Page 22
19
CONNECT THE REGULATOR TO THE LP TANK
VERY IMPORTANT:
- THE REGULATOR SHALL NOT BE IN A LOCATION THAT WILL ATTAIN A
TEMPERATURE ABOVE 140℉(60℃).
- THE REGULATOR SHALL INCORPORATE A PRESSURE RELIEF VALVE
OR OVERPRESSURE DEVICE.
- THE INLET OF THE PRESSURE REGULATOR SHALL BE FITTED TO
CONNECT THE TYPE I CONNECTION OF THE TANK VALVE PER ANSIZ21.81.
1) Make sure tank valve is in its full OFF position (turn clockwise to stop).
2) Check tank valve to assure it has proper external male threads (type I
connection per ANSIZ21.81).
3) Make sure all burner knobs are in their OFF position.
4) Remove the protective cap from LP tank valve. Always use cap and strap
supplied with valve.
5) Inspect valve connection port and regulator assembly. Look for any damage or
debris. Remove any debris. Inspect hose for damage. Never attempt to use
damaged or plugged equipment. Contact your local LP gas dealer for repair.
6) When connecting regulator assembly to the valve, hand tighten nut clockwise
to a positive stop. Do not use a wrench to tighten. Use of a wrench may
damage quick coupling nut and result in a hazardous condition.
7) Open tank valve fully (counterclockwise). Use a soapy water solution to check
all connections for leaks before attempting to light grill. If a leak is found, turn
tank valve off and do not use grill until a local L.P gas dealer can make repairs.
DISCONNECT THE TANK WHEN THIS GRILL IS NOT IN USE
1) Turn all the knobs off.
2) Turn the tank valve off fully (turn clockwise to stop).
3) Detach the regulator assembly from tank valve by turning the quick coupling
nut counterclockwise.
4) Install the protective cap back onto the LP tank valve.
OPD HAND WHEEL
OP
EN
g
CLO
SE
GAS CONNECTION