beautypg.com

Lincoln electric, L-5 l-6 – MK Products Weld Control User Manual

Page 23

background image

Weld Control Selector Guide - Page 16

For the Lincoln R3S-325 the following applies.

1. Connect the

black and white contactor leads extending from the

WC-1 or Cobramatic to the terminal strip on the R3S-325;

black

to

32 & white to 4. Place the unit in CLOSING CONTACTS

position (see Appendix for contactor information).

2. Plug the 115VAC plug extending from the WC-1 or Cobramatic

into a standard wall outlet or cut off the plug and wire

black to

32, white to 31 and green to ground lug.

3. Tape off WC-1

red and green leads and turn off Posa Start

switch as Posa Start is not used.

For all Lincoln CV power supplies except the R3S-325 the following applies. See section L-5 for the

R3S-325.

1. Connect the

black and white contactor leads from the WC-1 or

Cobramatic to the terminal strip on the Lincoln power supply;

black to 2 & white to 4. Place WC-1 or Cobramatic in CLOSING

CONTACTS position (see Appendix for contactor information).

2. Plug the 115VAC plug from the WC-1 or Cobramatic into a

standard wall outlet or cut off the plug and wire

black to 31, white

to

32 and green to ground lug.

3. Tape off WC-1

red and green leads and turn off Posa Start switch

as Posa Start is not used.

Note: Some Lincoln gas drives use slightly different numbering on the terminal strip. However, 2 & 4

are still the contactor and 31 & 32 are still the 115VAC. If using a gas drive in CC mode red and

green Posa Start leads must be connected. (see section L-8, 9 ).

Lincoln Electric

L-4

New Lincoln power supplies use a 14-Pin (X clocked) amphenol similar to the Miller machines, however,

the pins are clocked differently than the Miller (S clocked) amphenol.

1. Connect the

black and white contactor leads from the WC-1 or

Cobramatic to the 14-Pin amphenol;

black to d & white to pin C.

Place unit in CLOSING CONTACTS position (see Appendix for

contactor information).

2. Plug the 115VAC plug from the WC-1 or Cobramatic into a

standard wall outlet or cut off the plug and wire

black to J, white

to

a and green to pin B.

3. Tape off WC-1

red and green leads and turn off Posa Start

switch as Posa Start is not used.

115VAC

OUTPUT

CONTACTOR

LEADS

P/N 005-0659

Complete 25' cable with 14P

(X clocked) Amphenol attached.

Note:

If unit does not have a 14-Pin see section L-4 .

The PA-L1 Control (P/N 005-0676) comes equipped with a 14 Pin (X-clocked) amphenol connector and

simply plugs into any Lincoln CV-type welder that has a 14 Pin (X) socket. This unit operates on 42

volts and is for "CV" only. If the welder has a remote voltage control, it should be set on "Panel". The

contactor switch should be on "Remote". Most of the newer Lincoln shop machines now use a dinse

style connector (MK P/N 153-0755) which would have to replace the lug on the power cable of the

Prince XL spool gun.

P/N 005-0608

Complete 8' cable with 14P

(X clocked) Amphenol attached.

L-5

L-6

14-Pin

amphenol

MK P/n’s

LE P/n’s

Socket

153-1161

S-12020-32

Cord Clamp

411-0035

S-12024-2

Rubber Boot

301-0021

---