Pharmacode 39 (code 32), Rss-14 – Datalogic Scanning Pegaso User Manual
Page 117
Bar Code Parameters
Product Reference Guide
F-9
Send Check
Digits
This instructs the decoder to include any
enabled check digit(s) in the label which is
transmitted.
060B
On / Off
Off
On
Off
2nd Check
Digit Mod 11
Instructs the decoder to interpret any second
MSI check digit as modulo 11 instead of mod-
ulo 10.
060C
On / Off
Off
Off
Off
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0624
01 - 15
01
01
04
Maximum
Label Length
This feature specifies the maximum allowable
length of an MSI label. The length includes
check and data characters. Maximum Label
Length should be greater than or equal to Min-
imum Label Length.
0625
01 - 15
01
15
10
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0626
01 - 04
01
02
01
User ID
Specifies the symbology identifier (if any) that
is sent by the decoder when parameter Send
Code ID (Index 0025) is set to 3. "ASCII" code
zero (null) is used to indicate that an identifier
is not to be sent for the symbology.
0627
Any single
ASCII
character
(00 = Off)
'H'
'H'
'H'
Pharmacode 39 (Code 32)
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Pharmacode 39 (Code
32) symbology.
0110
On / Off
Off
On
Off
Send Check-
sum
Instructs the terminal to include the checksum
in the label transmission.
0112
On / Off
Off
Off
Off
Send Start/
Stop
Instructs terminals to prefix a Pharmacode 39
label with an “A” prior to transmission.
0113
On / Off
Off
On
Off
User ID
Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology.
0127
Any single
ASCII
character
(00 = Off)
'Y'
'Y'
'Y'
RSS-14
Enter 1 for On
and 0 for Off.
RSS-14
Enable
Enables/disables the RSS-14 symbology.
0800
On / Off
Off
On
On
RSS-14 to
UCC-EAN
128
Instructs the decoder to transmit the label data
as one or more UCC-128 labels. The trans-
mission will use the UCC-128 AIM identifier.
0804
On / Off
Off
On
Off
Code Parameter/ Description
I.D. #
Acceptable
Input
Defaults
Min
Max
Factory