beautypg.com

Pharmacode 39 (code 32), Rss-14 – Datalogic Scanning Pegaso User Manual

Page 117

background image

Bar Code Parameters

Product Reference Guide

F-9

Send Check
Digits

This instructs the decoder to include any
enabled check digit(s) in the label which is
transmitted.

060B

On / Off

Off

On

Off

2nd Check
Digit Mod 11

Instructs the decoder to interpret any second
MSI check digit as modulo 11 instead of mod-
ulo 10.

060C

On / Off

Off

Off

Off

Minimum
Label Length

Set the minimum label length to be less than
or equal to maximum label length.

0624

01 - 15

01

01

04

Maximum
Label Length

This feature specifies the maximum allowable
length of an MSI label. The length includes
check and data characters. Maximum Label
Length should be greater than or equal to Min-
imum Label Length.

0625

01 - 15

01

15

10

Read Verifi-
cation

Sets the number of times a label must be read
before it is transmitted.

0626

01 - 04

01

02

01

User ID

Specifies the symbology identifier (if any) that
is sent by the decoder when parameter Send
Code ID (Index 0025) is set to 3. "ASCII" code
zero (null) is used to indicate that an identifier
is not to be sent for the symbology.

0627

Any single

ASCII

character

(00 = Off)

'H'

'H'

'H'

Pharmacode 39 (Code 32)

Enter 1 for On

and 0 for Off.

Enable

Enables/disables the Pharmacode 39 (Code
32) symbology.

0110

On / Off

Off

On

Off

Send Check-
sum

Instructs the terminal to include the checksum
in the label transmission.

0112

On / Off

Off

Off

Off

Send Start/
Stop

Instructs terminals to prefix a Pharmacode 39
label with an “A” prior to transmission.

0113

On / Off

Off

On

Off

User ID

Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology.

0127

Any single

ASCII

character

(00 = Off)

'Y'

'Y'

'Y'

RSS-14

Enter 1 for On

and 0 for Off.

RSS-14
Enable

Enables/disables the RSS-14 symbology.

0800

On / Off

Off

On

On

RSS-14 to
UCC-EAN
128

Instructs the decoder to transmit the label data
as one or more UCC-128 labels. The trans-
mission will use the UCC-128 AIM identifier.

0804

On / Off

Off

On

Off

Code Parameter/ Description

I.D. #

Acceptable

Input

Defaults

Min

Max

Factory