beautypg.com

Environmental performance specifications, Durability performance specifications – Interlink Electronics FSR 400 Series User Manual

Page 21

background image

www.interlinkelectronics.com

19

FSR

®

Integration Guide


Environmental Performance Specifications

PARAMETER

TYPICAL R CHANGE

NOTES

Hot Operation

-15%

85°C after 1 hour

Cold Operation

-5%

-40ºC after 1 hour soak

Hot Humid Operation

+10%

+85°C, 95% RH, after 1hour

Hot or Cold Storage

-10%

-25ºC to +85°C, 120hrs

Hot Humid Storage Temperature

+ 30% of established nominal
resistance

+85°C, 95% RH, 240 hours

Thermal Shock

± 2% typical

-25ºC to +70°C, 10 Cycles,
15 minute dwell,
5 minute transitions

Note: Specifications are derived from measurements taken at 1000 grams.


Durability Performance Specifications

PARAMETER

TYPICAL R CHANGE

NOTES

Tap Testing

-10%

10 million actuations, 1kg, 4Hz

Constant Load

-5%

2.5 kg standing load, 24 hrs

Chemical Resistance

The following chemicals do not affect the operation when applied
to the outside of the sensor: cola, coffee, isopropyl alcohol, soap
solution, household cleaners. No others tested. Application is a
single drop on the exterior of the sensor that is allowed to soak
until evaporation and does not enter the sensor.

Sensitivity to Noise/Vibration

No effect

Note: Specification derived from measurements taken at 1000 grams.