Insinger RL-30 User Manual
Page 12
®
RL‐30 Undercounter May 2012 11 www.insingermachine.com 800‐344‐4802
PART 3 OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Chemical Connections:
The RL-30 is supplied with integral detergent and
rinse additive pumps and the chemical hoses are
located on the side of the dishmachine.
Detergent concentration should be between .25%
(.30oz/gal) and .30% (.38oz/gal). Note: Always
consult
chemical
manufacturer
for
proper
concentration.
Preparing for operation:
•
Locate the clear chemical pick up tubes on the
side of the unit
•
Identify the detergent pick up tube (smaller
diameter ID tube) and place it in the container
of commercial liquid detergent.
•
Place the rinse additive pick up tube (larger
diameter ID tube) in the container of commercial
liquid rinse additive.
Priming the system:
•
The detergent pump is self priming and runs
during the rinse/fill cycle. The amount of
detergent dispensed is controlled by the
speed of the peristaltic pump. This can be
adjusted by turning the control screw.
•
The rinse additive pump is located behind the
front kick panel. The pump is a diaphragm
type pump and can be primed by inserting a
screwdriver into the screw on the front/top of
the pump, turning counter clockwise and then
depressing the screw to begin the manual
priming. Make several compressions until you
see the rinse additive solution entering the
check valve on the other side of the pump.
The amount of rinse additive that is added to
the system can be adjusted by turning the
screw
clockwise
to
decrease
and
counterclockwise to increase. Once set, the
solution is then added automatically to the
rinse system.
Rinse pump
adjusting screw
and prime
Rinse pump
Control screw