HUBER+SUHNER MASTERLINE Extreme Hybrid User Manual
Installation manual, Masterline extreme hybrid

HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of
tools and accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product
warranty provided by HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these pro-
ducts. For advice concerning the general handling of these products please contact HUBER+SUHNER.
INSTALLATION
MANUAL
RRH END OF ASSEMBLY
Step 1
Mount the cable spool onto suitable de-reeling
equipment.
Start unwinding side where the braided tube is
attached (picture to the right). Do not pull side where
pulling tube is attached. Make sure, that the spool can
turn freely when unspooling.
Step 2
Rig a rope to allow cable assembly to be hoisted up.
Feed the rope through the loop in the braided tube
and down onto the cable hoist.
•
Pull Assembly up the mast
Important: NEVER pull on the divider or the breakout
(Fiber optic or power itself), only pull on the hybrid
cable below the divider using cable hoist.
Step 3
Remove cable tie from braided tube end to get
access to the housing .
•
Once the divider is at the desired height and
position, proceed to the next step. Do NOT yet fix it to
the mast.
Comment: take length of break-out and jumpers in
consideration when the divider is positioned on the
mast.
HUBER+SUHNER AG
Fiber Optics
MASTERLINE Extreme Hybrid
DOC-0000692200 Rev B
April 20, 2015
Page 1 of 12
Table of contents
RRH END OF ASSEMBLY
1
BASE STATION END OF ASSEMBLY
4
FIBRE OPTIC ALLOCATION
9
POWER CODING
10
MASTERLINE Extreme Hybrid