Troubleshooting

Problem

Cause

Action

Unit will not 

turn on

(no power)

Yellow or red wire not connected or
incorrect voltage

Check connections for proper
voltage (11~16VDC)

Black wire not connected

Check connection to ground

Fuse blown

Replace fuse

Unit has power 

(but no sound)

Speaker wires not connected

Check connections at speakers

One or more speaker wires touching
each other or touching chassis
ground

Insulate all bare speaker wires
from each other and chassis
ground

Unit blows 

fuses

Yellow or red wire touching chassis
ground

Check for pinched wire

Speaker wires touching chassis
ground

Check for pinched wire

Incorrect fuse rating

Use fuse with correct rating

Excessive 

skipping

Unit is not mounted correctly or
backstrap is not secure

Check mounting sleeve and
backstrap support

Physical defect in media
(CD, CD-R or CD-RW)

Check media for scratches

Err appears on 

display

Load/Eject operation error or disc is
in upside down

Press eject