Setup and installation – Pinnacle Systems SLT Series User Manual
Page 12

4
SLT Series
Setup and Installation
Important:
The Ground
Terminal must be connected
to a good ground connection,
not conduit. A bad ground
may keep the light curtain
from going GREEN in an
electrically noisy environment.
W
W
W
W
Wiring Dia
iring Dia
iring Dia
iring Dia
iring Diag
gg
ggrrrrram
am
am
am
am
Receiver
Cable
Black
White
Green
Red
Red/Black
Blue
Blue/Black
Black/White
White/Black
Green/Black
Orange
Orange/Black
Line (+24VDC)
Neutral (-24VDC)
Earth
In series
with Stop
Circuit
Auxiliary N.O.
Auxiliary Common
Auxiliary N.C.
Optional
Latching Reset
Cincinnati Interface Input
+24VDC = Red
Ground = Guarded
External Relay Check Input
<---||---\\-- +24
External N.O. monitored contacts
+/- 24VDC
Solid State Output Only
24VDC Input Power
Receiver
Cable
Black
White
Green
Red/Black
Blue/Black
Orange/Black
+ 24VDC
- 24VDC
Earth
Optional
Latching Reset
Cincinnati Press
+24VDC = Red
Ground = Guarded
+ 24VDC
#1
#2
24VDC out when Green
24VDC out when Green
External Relay Check Input
<---||---\\-- +24
External N.O. monitored contacts
4
5
9
10
11
12
13
15
16
1
2
7
Mechanical Safety Relay Outputs
120VAC or 24VDC Input Power