AXING SKQ-40-0x User Manual
Page 8

Operating manual | SKQ 40-00 | SKQ 80-00 | 8PSK/QPSK | QAM Quattro/Octo Modules
8
2015-06-07 | © AXING AG Switzerland | We assume no liability for design changes, type changes, errors and misprints
2.1.1.
Power supply in the headend base unit
A certain number of modules including LNB can be supplied depending on the headend base unit.
SKS 4-00 with
SKZ 5-01 (10 A)
SKS 40-00* with
SKZ 5-01 (10 A)
SKS 40-00* with
SKZ 5-04
(2x10A)
SKS 8-00 with
SKZ 6-00 (18 A)
SKQ 40-0x
1.5 A + LNB current
consumption
4 4 4 8
SKQ 80-0x
3 A + LNB current
consumption
3 3 4 5
*Please note: The SKS 40-00 is supplied without power supply unit and remote control.
2.2.
Stand-alone operation of the SKQ 40-00 / 80-00
Before installing the SKQ 40-00 / 80-00, the power supply must be switched off.
To avoid dangerous overvoltages (danger: risk of fire/death), the module must be grounded according to EN
50083-1, EN 60728-11:2010. Use the grounding screw attached to the device.
For operation without a basic unit, the outputs of two modules must be combined with a distributor.
2.2.1.
Power supply in stand-alone operation
If the SKQ 40-00 / 80-00 is operated in stand-alone mode, the power supply is directly connected via the DC
power cord of the power supply unit. This requires a separate power supply unit SKZ 5-03. Additional units are
connected via the DC loop output. One SKZ 40-00 DC connection cable each is included in the scope of delivery
of the SKQ 40-00 / 80-00.