Cabinet Dimensions:
Indoor Model
7.5” W x 6.25” H x 2” D
(19cm W x 15.9cm H x 5cm D)
Outdoor Model
13.25” W x 9” H x 3.5” D
(33.7cm W x 22.9cm H x 9cm D)
Power Specifications:
Indoor Model
Plug-in Transformer, Class 2, UL Listed, CSA Certified
(or equivalent)
• Input:
120 VAC 60 Hz, 0.5A
• Output:
24 VAC 60 Hz, 18 VA
Outdoor Model
Built-in Transformer, Class 2, UL Listed, CSA Certified
(or equivalent)
• Input:
120 VAC 60 Hz, 0.5A
• Output:
24 VAC 60 Hz, 20–30 VA
Maximum Current Load Per Zone:
0.30 Amps @ 24 VAC
Maximum Current Load For Pump/Master Valve:
0.30 Amps @ 24 VAC
Total Maximum Current Output:
One zone plus pump/
master valve. Must not to exceed 0.60 Amps
@ 24 VAC
Temperature Limit Range:
Operating – 14°F to 140°F (-10°C to 60°C)
Storage – -22°F to 149°F (-30°C to 65°C)
.
Automatic Circuit Protection
A built-in circuit protection circuit designed to prevent
damage to the timer caused by a faulty valve solenoid or
pump start relay. The instant an overload current condi-
tion is detected, the affected zone is turned OFF and the
next zone in the watering sequence is turned ON.
Automatic Control Valve
An electrically activated valve which controls the flow of
water from the source to the sprinkler zone.
Scheduling Advisor
An exclusive Toro software program which guides you
easily through the ECXTRA programming process to
select the optimum watering schedule for your landscape.
Calendar
Schedule
A Calendar schedule enables you to select specific days
of the week to water, for example, Monday, Wednesday
and Friday. This is a seven-day schedule which starts on
Sunday and ends on Saturday.
Day Exclusion
This feature enables you prevent watering on specific
days of the week when using an Interval or an Odd/Even
watering day schedule.
Indoor Timer Model
A timer model specifically designed for installation in a
protected environment, such as a house or garage.
Manual Operation
Operation of the timer by manually starting a watering
cycle or individual zone.