Step-By-Step Instruction Guide

Follow separate Foam Gasket Instructions

to install the 4 four foam strips on the Backplate.

Carefully break Security Seal located on the

underside of the Lamp cardboard sleeve.

Carefully slide Lamp out from protective sleeve. Be

sure to use cotton gloves (included) guaranteeing a

clean Lamp free from fingerprints.

Slide the Lamp’s porcelain end-cap (with the 4 pins)

through clamp bracket. Be sure to notice the

Tension Lever is down.

Tension Lever

is DOWN

Once the Lamp’s end-cap is in place, pull the

Tension Lever UP to lock the Lamp in place. If the

Lever is loose, just turn Lever clockwise a turn or so.

Tension Lever

is UP locking

Lamp in place

While holding the SAME side of the Lamp attached

to the clamp, carefully push on the white plug.

NOTE: Although the Lamp is fairly strong, too much tension from

the opposing side may break the Lamp.

Once Lamp is installed, place and screw Turbulator to

the top of the Reflecting Tube. The air must pass

through this Turbulator as it enter the Reflecting Tube.

Cut-out the ‘Smart Template’ from the side of the

Purifier’s outer carton.

Did you throw

out the box?

Don’t worry!

Just cut a 10.25”

x 6.25” opening

into the duct!

Draw around the ‘Smart Template’ outlining where

the Purifier will be installed

Return or Supply

Installation?

We suggest

Return, but

can be easily

installed on the

Supply.

Cut around outline.

Angle the purifier so it easily fits into the duct

opening.

Use the self-taping screws (included) to mount

the purifier to the duct. Just plug into an electrical

socket and turn on the red toggle switch.

Only break the

security seal

AFTER you

visually inspect

the Lamp.

1

3

4

5

6

7

8

10

11

12

2

9

If the White Plug
does not push
on easily, just
rotate the plug
180º

Up-flow System?
Horizontal duct?
Not a problem. The
Reflecting Tube &
Lamp are easily
rotatable 180°.
Just visit back
page for
instructions.

R4000

INSTALLATION

MANUAL

Understanding The ‘Smart System’ LED Status Display

Congratulations on the purchase & installation of your new Sanuvox Ultraviolet Air Purifier. Sanuvox UV Air Purifiers are the
most advanced Air Purification System available having been proven to destroy up to 99.999% of Biological & chemical
contaminants that circulate throughout your home or facility. Sanuvox Systems have been tested by The EPA (Environmental
Protection Agency), The National Homeland Security Research Center, Medical Universities and Independent 3rd Party
Laboratories.

8

When the HVAC fan is on, ALL four
LED lights should be on.

If the Ballast LED is on and the Lamp
LED is off, the UV Lamp is not
functioning.

If both the Ballast LED is off and the
Lamp LED is off, the ballast is not
functioning.

Visit the back page for
wiring instructions and the Trouble
Shooting.

POWER = RED
BALLAST ON = RED
SENSOR ON = AMBER
LAMP ON = AMBER

Please note that the R4000GX ballast was changed in 2009. Those
R4000GX manufactured prior to 2009 had the following LED colors:
Power = RED / Ballast = GREEN / Sensor = AMBER / Lamp = BLUE