beautypg.com

Table 2 – ADLINK RuffSystem 800 User Manual

Page 7

background image

RuffSystem Setup

RuffSystem

User’s Guide

3

Table 2

lists the current draw values of the RuffSystem with the COM 840.

Operating configurations:

In-rush operating configuration consists of one COM 840, 2GB DDR2 RAM, AMI BIOS, I/O board,
EBX Baseboard, AC/DC external digital power supply, DC/DC internal power module, LCD monitor,

SATA 2.5" HDD, on-board Compact Flash drive, keyboard and mouse.

Idle operating configuration consists of the same items as the In-rush configuration.

BIT* = Burn-In-Test. Operating configuration consists of the same items as the Idle configuration as
well as four serial loop backs, one parallel port with loop back, two Ethernet connections, and four
external USB Compact Flash loop backs.

Table 2. System Power Requirements (COM 840 with EBX Baseboard, 1.6 GHz Pentium M CPU)

Input Type

In-rush Current
(@ 104.26W Power)

Typical Idle Current
(@ 37.96W Power)

Typical BIT* Current
(@ 48.43W Power)

+14VDC

7.45A 2.71A

3.46A

+16VDC

6.52A 2.38A

3.03A

+18VDC

5.79A 2.11A

2.69A

+20VDC

5.21A

1.90A

2.42A

+22VDC

4.74A 1.73A

2.20A

+24VDC

4.34A

1.58A

2.02A

+26VDC

4.01A 1.46A

1.86A

+28VDC

3.72A 1.36A

1.73A

+30VDC

3.48A 1.27A

1.61A

+32VDC

3.26A 1.19A

1.51A