Specifications bbe 422a, Service, Wsrranty – BBE Sonic Maximizer BBE 422A User Manual
Page 14: Maintenance
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Specifications BBE 422A
Frequency Response
Bypass
Process Mode
DC to 20kHz
program controlled
Absolute Noise In Process Mode -87dBu below rated max output of OdBu
Total Harmonic Distortion
in Process Mode
Input Characteristics
Input Impedance
Nominal Input Level
Maximum Input Level
Output Characteristics
Minimum Load Impedance
for full output level
Nominal Output Level
Maximum Output Level
less than 0. l %
50K Ohms
-lOdBu
+16dBu
■ tOdBu Level
1 K Ohm
-lOdBu
+16dBu
Power Requirements
U.S. Model
Standard Model
AC Line fuse protected
Terminations/Connectors
Rear Panel
Dimensions
Hx 19" Wx 5V/ D
Weight
4
'/2
lbs. {2.5Kgs)
NOTE: OdBu = 0.775 Vrms
100-120Vac, 50/60HZ, 10 Watts
200-240Vac, 50/60 Hz, 10 Watts
U.S. Model, 250Vac,
1/2A Fastblow type fuse
Standard Model, 250Vac,
. 125A Fastblow type fuse
RCA Jacks and '/
4
" Phone Jacks
Standard 1U single rack
Service
We recommend that if at all possible a BBE 422A which requires service be sent to our facility in Huntington Beach, CA.
We requestthat a “RETURN AUTHORIZATON” be issued by the dealer from whom you purchased the unit. If this is not poss
ible, call BBE Sound, Inc. directly at (714) 897-6766, to obtain a ‘RETURN AUTHORIZATION”. Include a copy of the bill of
sale with the unit when it is shipped to BBE Sound, Inc. so that the service can be expedited.
As the repair turnaround time is minimal, we request that the unit be sent to BBE Sound, Inc. We also need to add reliability
data to our files so that future revisions may be undertaken, if necessary, to improve the product.
Wsrranty
Warranty registration of the unit to BBE Sound, Inc. is not necessary. It is strongly recommended that you retain a copy of
the bill of sale for future reference.
IT IS THE SOLE RESPONSIBLIITY OF THE END USER TO PROVIDE THE BILL OF SALE OR OTHER MEANS OF
PROOF OF PURCHASE TO VALIDATE THE WARRANTY IF WARRANTY SERVICE IS REQUESTED.
The BBE 422A is warranted against defects in material and workmanship for a period of one (1) year from date of
purchase from BBE Sound. Inc. or from an authorized dealer.
During this period, we will repair units free of charge providing that they are shipped prepaid to BBE Sound, Inc., 5500
Bolsa Ave., Suite 245, Huntington Beach, CA 92649. We will pay return UPS shipping charges within the USA. All charges
related to non-UPS shipping, including customs clearance, will be billed. The warranty will be honored for the longer of either
90 days from the date of any service or the remainder of the original 1 Year factory warranty.
This warranty will be considered null and void by BBE Sound, Inc. if any of the following is found;
1. The equipment has been physically damaged.
2. The equipment shows signs of abuse.
3. The equipment has been electrically damaged by improper connection or attempted repair by the customer or a
third party.
4. The equipment has been modified without authorization.
5. The bill of sale indicates that the purchase date of the equipment is not within the warranty period.
All non-warranty repairs are warranted for a period of 90 days from the date of service.
BBE Sound, Inc. is NOT LIABLE FOR CONSEQUENTIAL DAMAGES. Should the unit fail to operate for any reason, our
sole obligation is to repair it as described above.
DO NOT RETURN ANY PRODUCT TO THE ABOVE ADDRESS WITHOUT INSTRUCTIONS AND AUTHORIZATION
ISSUED BY THE ABOVE LOCATION.
Maintenance
Maintenance of the BBE 422A is limited to proper cleaning of the unit with mild household cleaner such as Formula 409™
or Windex'T The chassis and cover are steel finished with a durable polyurethane paint, while the front panel is an anodized
aluminum extrusion.
There are no user replaceable parts and the unit should not be opened for any reason unless you are a qualified technician.
Calibration should be performed if parts are replaced or if a performance check-out indicates a problem with calibration.
Long term use has shown that over the life of this unit there is little or no drift of the components in the BBE 422A which
would cause a change in calibration. A very conservative design philosophy has resulted in a piece of equipment which runs
very cool and should give years of frouble-free service.