Component testing information a warning, A caution, X ■ i' jr >l i – Amana Pi143415N User Manual
Page 3
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Component Testing Information
A WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
Illustratiort
Component
Test Procedure
Results
053584
Control limit
Normally Closed
Verify proper operation.
Closed
245°F
Open
275“F
Continuity
Infinite
If open at room temperature, replace.
31715201— LH
31715202— RH
Opening
Hinge
Carefully open the hinge fully, and
insert a wooden dowel or screwdriver
bit into opening.
Remove top and bottom screws
securing hinge.
Slide hinge top towards rear of unit
and guide hinge out through frame
opening or storage drawer.
A CAUTION
Do not place hands in hinge area when
oven door is removed. Hinge can snap
closed and pinch hands or fingers.
065780
Door lock switch
Switch connection in following
positions:
Unlocked
Locked
Set ERC to Clean
COM-NO=Open, COM-NC=Closed
COM-NO=Closed, COM-NC=Open
Lock LED should flash
Lock LED and Oven LEO should
illuminate, If Lock LED does not
illuminate, check switch and wiring.
305797
Door plunger switch
Remove switch from unit and measure
the following points:
C-NC
C NO
Plunger in infinite. Plunger out continuity.
Plunger in continuity, Plunger out infinite.
31797301
Autolatch assembly
with door plunger
switch
Disconnect wires and test for
continuity per diagram.
NC
NC
LI L2 COMI PM
com
!
no
X ■ I' Jr >L i
120 VAC LedVUntocfc
Motor
Door
Switch
April 1999
RT2320003 Rev. 9