9. Function chart
SART STATUS
BUZZER
RED LED
OFF
OFF
OFF
STANDBY MODE
(TEST or ON)
OFF
FLASHING
EVERY 2 SECONDS
ACTIVELY
TRANSPONDING
(TEST or ON)
ON
EVERY 2 SECONDS
ON
10. Fault Finding
Fault finding is limited to performing the self test and verifying the SART response on
the radar.
11. Servicing
The SART contains no user-serviceable parts, and consequently should be returned
to an authorised Kannad Marine service agent for repair. Ensure compliance with the
appropriate regulations for transportation of Lithium material, as detailed in the
Transportation section on the front inside cover.