beautypg.com

Condensation, Awarning, Smoke/odor – Kenmore POWER MISER 153.336951 User Manual

Page 19: Operational conditions, Smelly water, Air” in hot water faucets, Condensation smoke/odor, Operational conditions -24, Smelly water “air" in hot water faucets, Troubleshooting guide (cont*d)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Troubleshooting Guide (cont*d)

CONDENSATION

Whenever the water heater is filled with cold water, a certain

amount of condensation will form while the burner is on. A

water heater may appear to be leaking when in fact the water is

condensation. This usually happens when:

• When a new water heater is filled with cold water for the

first time.

• When gas burns and water vapor is produced in water

heaters, particularly high efficiency models where flue tem­
peratures are lower.

• When you use large amounts of hot water in a short time

and the refill water is very cold.

Moisture from the products of combustion condense on the
cooler tank surfaces and form drops of water which may fall
onto the burner or other hot surfaces to produce a “sizzling" or
“frying” noise.

Excessive condensation can cause pilot outage due to water run­
ning down the flue tube onto the main burner and putting out

the pilot.

Because of the suddenness and amount of water, condensation

water may be diagnosed as a “tank leak”. After the water in the

tank warms up (about 1-2 hours), the condition should disap­
pear.

Do not assume the water heater is leaking until there has been
enough time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The
water heater must be sized properly to meet the family’s demands

for hot water including dishwashers, washing machines and

shower heads.

Excessive condensation may be noticed during the winter and

early spring months when incoming water temperatures are at

their lowest.

Good venting is essential for a gas fired water heater to operate

properly as well as to carry away products of combustion and

water vapor.

AWARNING

HOTTER WATER CAN SCALD; Wkter heaters are intended to
ptY^uce hot water. Water heated to a temperature which will
satisfy clothes washing, dish washing, and other sanitizing needs
can said and permanently injure you upon contact Some peo­
ple are more likely to be permanently injured by hot water than

others. These inciude the elderly, children, the infirm, or physical-
ly/mentally handicapped. If anyone using hot water in your home
fits into one of these groups or if there is a iocal code or state iaw
requiring a certain temperature water at the hot water tap, then
you must take special precautions. In addition to using the lowest
possible temperature setting that satisfies your hot water needs,
a means such as a mixing v^ve, shouid be used at the hot water
taps used by these people or at the water heater. Mixing valves
are available at plumbing supply or hardware stores. Follow man­
ufacturers instructions for instailation of the vaives. Before

changing the factory setting on the thermostat, read the
"Temperature Regulation’’ section in this manual.

SMOKE/ODOR

It is not uncommon to experience a small amount of smoke and
odor during the initial start-up. This is due to burning off of oil
from metal parts, and will disappear in a short while.

Operational Conditions

SMELLY WATER

In each glasslined water heater there is installed at least one

anode rod (see parts section) for corrosion protection of the
tank. Certain water conditions will cause a reaction between this

rod and the water. The most common complaint associated with
the anode rod is one of a “rotten e^ smell”. This odor is derived
from hydrogen sulfide gas dissolved in the water. The smell is
the result of four factors which must all be present for the odor
to develop:

a. a concentration of sulfate in the supply water.
b. little or no dissolved oxygen in the water.
c. a sulfate reducing bacteria within the water heater. (This

harmless bacteria is non-toxic to humans.)

d. an excess of active hydrogen in the tank. This is caused by

the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,

and then chlorinating the water heater tank and all hot water
lines. Contact Sears Service for funher information concerning
an Anode Replacement Kit #9001453 and this Chlorination
Treatment.

If the smelly water persists after the anode replacement and chlo­
rination treatment, we can only suggest that continuous chlori­
nation and filtering conditioning equipment be considered to

eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.

“AIR” IN HOT WATER FAUCETS

AWARNING

HYDROGEN GAS; Hydrogen gas can be produced in a hot
water system that has not been used for a long period of tíme
(generally two weeks or more). Hydrogen gas is extremely
flammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet
be opened for several minutes at the kitchen sink before any
electrical appliances which are connected to the hot water sys­
tem are used (such as a dishwasher or washing machine). If

hydrogen gas is present, there will probably be an unusual
sound similar to air escaping through the pipe as the hot water
foucet is opened. There must be no smoking or open flame

near the faucet at the time it is open.

23