A. TROUBLESHOOTING

VALVE POSITION INDICATORS: Depending on

the valve position, the following indicators show in
the display:

INDICATOR

VALVE POSITION

Serv.............................................service
Fill .............................................. fill
Brine .......................................... brining/brine rinse
Bkwash....................................... backwash
Rinse.......................................... fast rinse

When the valve is rotating from one cycle to another,
both indicators flash. For example, if the valve is in
transition between fill and brining, both Fill and
Brine flash. Upon reaching brining position, Fill

goes off and Brine is on steady. The time display
shows the minutes of the cycle remaining.

NOTE: If the faceplate is left in a diagnostic
display (or a flashing display when setting times
or hardness), present time automatically returns

if a button is not pressed within # minutes. To
return to the diagnositc display, repeat step 2.

OTHER INFORMATION: While in this diagnostic
screen, the following information is available and

may be beneficial for various reasons. This informa­
tion is retained by the computer from the first time
electrical power is applied to the faceplate.

^ Press A to display the number of days this face

plate has had electrical power applied.

^ Press V to display the number of regenerations

initiated by this faceplate since the HF code number

as entered.

Press the ON /OFF-HOLD button to advance the
valve to each position and observe the switch
and position indicators to verify component op­
eration, or to possibly isolate a defect.

Press and hold the SELECT button for 3 seconds
untile

•HF32 shows.

SALTSIGNAl
.EVEilEVEL

1 ir 11

8

nr JO

7

4
3
2

This code identifies the softener nominal capacity
size. Df the wrong number shows, the softener will
operate on incorrect programming. Do the follow­
ing as needed.

HF32 does show—Press the SELECT 1 button to re­
turn the present time display.

To change HF number — Press the UP or DOWN
button until HF32 shows. Then, press the SELECT

1 button and reset the timer^pages 1-3 and 1-4.

TIMER PWA REPLACEMENT:

Be sure the valve is in

service position when replacing the timer PWA (ob­
serve valve cycle indicator).

If, after installing and programming the replacement
timer PWA, the valve is not in service position, do the
following to assure correct cycle orientation, or timing,
between the faceplate and valve.
Use the MANUAL ADVANCE procedures, page 5-4.
With the RECHARGE NOW button, advance through
the recharge cycles until the valve stops in service posi­
tion, and RECHARGE no longer flashes in the display.
NOTE: The valve motor may automatically drive
through several valve positions while searching for
service. If an error code occurs, unplug the transform­
er, then plug in again.