Troubleshooting Guide (cont’d)
Operational Conditions
SMELLY WATER
Tn each water heater there is installed at least one anode rod (see
parts section) for corrosion protection of th e tank. Certain water
conditions will cause a reaction between this rod, and the water.
The most common complaint associated with the anode rod is
one of a “rotten egg smell”. This odor is derived from hydrogen
sulfide gas dissolve in the water. The smell is the result of fxsur
factors which must all be present for the odor to develop;
a, a concentration of sul fate in the supply water,
b, little or no dissolved oxygen in the water,
c, a sulfate reducing bacteria within the water heater,
(This harmless bacteria is non- toxic to humans.)
d, an excess of active hydrogen in the tank. This is caused
by the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater
models by replacing the anodc(s) with one of less active material,
and then chlorinating the water heater tank and all hot water
lines. Contact the local Scars Service Center for further informa
tion concerning an .Anode Replacement Kit #9001453 and this
Chlorination Treatment,
If th e smelly water persists after the anode replacement and, chlo
rination treatment, we can only surest that continuous chlori
nation and, filtering conditioning equipment be considered to
eliminate the water problem.
Do uot remove tlie auode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.
"/IfR" IN HOT WATER FAUCET’S
AWARNING
HYDROGEN GAS: Hydrogen gas can be produced in a
hot water system that has not been used for a long peri
od of time (generally two weeks or more). Hydrogen gas
is extremely flammable and explosive. To prevent the
possibility of injury under these conditions, we recom
mend the hot water faucet be opened for several min
utes at the kitchen sink before any electrical appliances
which are connected to the hot water system are used
(such as a dishwasher or washing machine). If hydre^en
gas Is present, there will probably be an unusual sound
similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open
flame near the faucet at the time It Is open.
RUMBLING NOISE
In some water areas, scale or mineral deposits will build up on
your beating dements. This build,up will cause a rumbling noise.
Follow “Element Cleaning/'Rcplaccment” instructions to clean
and, replace the elements.
HIGH TEMPERATURE SHUT OFF SYSTEM
The water heater has a high, limit shut off system with a reset
button located on the thermostat.
Follow the resetting instructions which refer to the high limit
behind the access panel,
NOTE; If your water heater is connected to an “OFF PEAK”
clock, and uses the “3 wire lead” wiring diagram in the
“‘Wiring Diagram” section, then the vrater heater will have a
hi'liinit on both the upper and lower thermostats. Follow
the instmetions to reset the hhlimit behind the upper and
lower access panels,
• Before beginning, turn “OFF” electrical power supply to the
water heater.
AWARNING
HAZARD OF ELECTRICAL SHOCK! Before removing
any access panels or servicing the water heater, make
sure the electrical supply to the water heater Is turned
“OFF”, Failure to do this could result in DEATH, SERI
OUS BODILY
injury
;
or
PROPERTY DAMAGE.