Operating Instructions

Delay Start Operation

To program delay start:

1. Turn unitoff (press OFF pad).

2. Press DELAY START pad. Display flashes currently

programmed temperature setting.

3. Program new temperature setting (if desired) using

VI Apad-

NOTE:

Current temperature setting is used if not

changed within 5 seconds.

4. Select desired operating mode and fan speed.

5. Press DELAY START pad. Display flashes currently

programmed delay time—1 through 24 (hours).

6. Program new delay time (if desired) using

\/

|

pad.

NOTE:

Current delay time is used if not changed within

5 seconds.

7. Press DELAY START pad to start timer. Display

shows time remaining until unit automatically starts.

At programmed time, unit automatically starts in

programmed operating mode.

NOTE:

Timer automatically starts after 5 seconds if

DELAY START pad is not pressed.

To program automatic stop:

1. Start air conditioner in desired operating mode. If

unit is already in desired mode, go to step 2.

Press DELAY START pad. Display flashes currently
programmed time—1 through 24 (hours).

Program new time (if desired) using

\/

| ^ pad.

NOTE:

Current time is used if not changed within 5

seconds.

4. Press DELAY START pad to start timer. Display

shows time remaining until unit stops. When
programmed time elapses, unit automatically stops.

NOTE:

Timer automatically starts after 5 seconds if

DELAY START pad is not pressed.

To cancel delay stop program, press DELAY START pad
after timer starts counting down, or turn unit off (press
OFF pad).

2

.

3.

Adjusting Airflow Direction

See Figure 38. Position of air discharge vent louvers
determines direction of airflow from vent. Direction can

36 adjusted upward, downward, left, and right.______

Figure 38.

Airflow from Air Discharge Vent

1. Airflow direction control lever

2. Air discharge vent horizontal louvers

To adjust airflow upward or downward, move horizontal

louvers on outside of air discharge vent up or down.

To adjust airflow left or right, move airflow direction control

lever left or right.

Energy Saving Tips

In addition to operating air conditioner in energy-saving
mode, savings of energy and money can be realized by:

• Increasing insulation in walls and ceilings.

■ Closing all heating and ventilation diffusers or vents

(including furnace cold air return vent) in area being
cooled.

• Closing drapes or blinds on windows that receive

direct sunlight. Install window coverings or awnings
on windows not currently covered.

• Adequately ventilating attic. Heat build-up in attic adds

to air conditioner cooling load.

• Avoiding use of heat-producing appliances during

hottest parts of day.

• Turning off lights and appliances when not needed.

• For maximum efficiency and cooling, vent door should

be closed whenever air conditioner is cooling.