TROUBLESHOOTING
PRODUCT SPECIFICATIONS
Before calling for service, try the suggestions below to see whether you can solve your
problem without outside help.
PROBLEMS
CHECK POINT
SOLUTIONS
Dehumidifier does not
work when pressing
the POWER ON
button.
Is the power cord plugged into
a grounded 3-prong outlet?
Is BUCKET FULL light on?
Does BUCKET FULL light
appear after emptying the
water bucket?
Plug the power cord securely into a
grounded 3-prong outlet.
Empty the water bucket and
re-install.
Check the float switch to make sure
it is free and not obstructed.
Dehumidifier is
operating, but the unit
is not drawing any water
Is the compressor running as
well as the fan?
The unit may be in the defrost
mode. The fan is running but not the
compressor. The unit will return to
dehumidification automatically.
Loud noise and/
or vibration during
operation.
Is the unit on a level surface?
Move the unit to a level surface.
Sounds.
Sounds like flowing water
during and after operation.
It makes a pinging sound.
This is the normal sound of the
refrigerant flowing through the coils.
Normal sound of expansion and
contraction caused by temperature
changes.
Dehumidifier is not
running efficiently
Are the filter and grill dirty?
Is indoor temperature under
65°F?
Clean the FRCNT GRILL and AIR
FILTER.
Although the unit will dehumidify at
temperatures below 65 degrees,
there is a potential for frost to develop
which may inhibit the unit’s efficiency
Unit is discharging
warm air.
Normal: Compressor and electric motor
discharge a small amount of heat.
Water does not drain
through hose.
Check the DRAIN CCNNEC-
TCR. Is it installed correctly?
Check the drain hose for
kinks or obstructions.
Re-install drain hose according
to this manual.
Flatten the hose or remove block
age.
Classification
Specification
Remark
Model
50351
50501
50701
Power Supply
AC 115V/60HZ
AC 115V/60HZ
AC 115V/60HZ
Moisture Removal
35 Pint
(16.5liters)
50 Pint
(23.5liters)
70 Pint
(32.outers)
24-Hour Period
Control Type
Electronic
Electronic
Electronic
Refrigerant
R-410a
8.46 CZ(240g)
R-410a
10.58 OZ(300g)
R-410a
10.93 OZ(310g)
Humidity Setting
LC, 35-70%
LO, 35-70%
LO, 35-70%
5% Increments
Cycle Timer
3, 6, 12 Hours
3, 6, 12 Hours
3, 6, 12 Hours
Delay Time
1-12 Hours
1-12 Hours
IHour Increments
Fan Motor Speed 2 Stages:High,Low
Auto,High,Low
Auto,High,Low
3 Stages
Cperating Temp.
SeT-OOT
36^-99^
36^-99^
Dimensions
13.0X20.9X9.3 in
14.6X23.3X12.4 in
14.6X23.3X12.4 in
330X530X235 mm 370X590X315 mm
370X590X315 mm
Net Weight
29.76 lbs
(13.5Kg)
40.12 lbs
(18.2Kg)
44.75 lbs
(20.3Kg)
Bucket Capacity
10.6 Pint
(5.outers)
19.4 Pint
(9. niters)
19.4 Pint
(9.1 liters)
12