Allersearch Nomad NexGen User Manual
Page 3

1. MAIN SPECIFICATIONS
page 2
2. IMPORTANT SAFEGUARDS
page 2
3. COMPRESSOR OPERATING
INSTRUCTIONS
page 3-4
3.1 Mains operation
page 3
3.2 Operation with cigarette-lighter
socket
page 3
3.3 Fitting the battery (OPTIONAL)
page 3
3.4 Operation with battery (OPTIONAL)
page 4
3.5 Battery recharge (OPTIONAL)
page 4
TABLE OF CONTENTS
1. MAIN SPECIFICATIONS
The NOMAD
®
NexGen has been designed and developed as a handy, lightweight and portable nebuliser
therapy system. Its main feature is practicality in use, especially for travellers and those who require nebuliser
therapy away from home and frequently. The NOMAD
®
NexGen can be operated from mains voltage, through
the car lighter socket in cars, caravans, boats or from its own rechargeable battery (battery purchased as
a separate item).
The NOMAD
®
NexGen nebuliser system is complemented by a new-generation jet nebuliser bowl which
features a high nebuliser output performance, optimal particle size to ensure deep penetration into the lungs
and a non-spill feature that ensures no loss of medication if the nebuliser is accidentally dropped.
2. IMPORTANT SAFEGUARDS
This is a medical device for home use and may only be used with medication prescribed or
recommended by a doctor.
Before using the unit for the first time, and periodically throughout its life, check the power supply cord for
any damage; if damage is apparent do not use. Take the unit immediately to an authorised service centre
or your dealer.
• Children and disabled persons should always use the unit under strict supervision of an adult who has
read this manual.
• Some components are small enough that children could swallow them; keep the unit out of reach of
children.
• The unit must not be used in the presence of inflammable gases such as oxygen nitrous oxide or anesthetic
substances.
• The power supply unit provided with the NOMAD
®
NexGen can be used worldwide by using suitable
adapters for the specific country where it is to be used. Ask for information at the nearest authorized
service centre or your dealer.
Do not handle the plug of the power supply unit with wet hands and do not use the unit in wet
environments (for example while in the bath or shower). Never immerse the unit in water; should
this accidentally occur, unplug it immediately. Do not touch the unit until the plug has been removed from
the power socket. Take the unit immediately to an authorized service centre or your dealer.
• The case of the nebuliser therapy unit, power supply and battery are not protected against the ingress of
liquids. Never wash the unit under running water or by soaking. Keep away from sprays of water or other
liquids.
• Do not expose the Battery version unit to cold temperatures.
• Do not place the aerosol therapy unit, battery and power supply unit near sources of heat, in direct sunlight
or in excessively warm environments.
• Do not obstruct or place objects in the air inlet or front of air filter.
• Repairs should be carried out by authorised personnel only. Unauthorised repairs will invalidate the
warranty and may represent a hazard to the user.
• The Manufacturer, the Retailer and the Importer are responsible for safety, reliability and performance
only if: a) the unit is used following the instructions for use; b) the electrical system of the premises where
the unit is used is in conformity with current laws.
4. NEBULISER OPERATING
INSTRUCTIONS
page 5-6
4.1 Jet Nebuliser Bowl
page 5
4.2 Instructions for aerosol therapy
page 6
4.3 Cleaning and disinfection
page 6
5. AIR FILTER
page 7
6. TROUBLESHOOTING
page 7
7. SPARE PARTS
page 7
8. TECHNICAL SPECIFICATIONS
page 8-9
2