VI. SET-UP

To set up the ORB, fi rst determine if an Ethernet or Serial Connection is being used.

FOR ETHERNET CONNECTION

Requires cross-over cable.

1. Go to Control Panel, choose Network Connections.

2. Identify the correct Network Connection, not a wireless connection.

3. Choose Properties of chosen Network Connection.

4. Choose Properties of the TCP/IP Protocol.

5. Write down the current computer IP address.

6. Change the computer IP address to 192.168.1.171 with a sub-address of 255.255.255.0; gateway is left blank

7. Apply changes. Rebooting the computer may be necessary.

8. Connect the cross-over cable from the Ethernet port on the ORB to the Ethernet port in the computer;

watch Network icon for connectivity.

9. Launch a web browser.

10. Type 192.168.1.170 into the address window.

11. Log into the ORB using a web browser.

User Login = Admin

Password = Admin

NOTE: If using Internet Explorer, the time must be changed to the local time.

12. Choose Set Up EtherNet on the main screen

13. Match the ORB IP address to the assigned IP address, assigned by your IT group.

14. Choose Update ORB

15. Confi rmation screen will appear, review and click OK

16. Disconnect the cross over cable and plug the ORB into your network.

17. Open new Internet browser and type in new IP address.