beautypg.com

Typical system connections, Connections, Typical system connections connections – Panasonic WV-7230D User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TYPICAL SYSTEM CONNECTIONS

Mounting Bracket _
wv-7030

r

Pre-wired cable

WV-CA50

Indoor Receiver

WV-RC100

TTX

AC 24V 60Hz

System Controller

WV-CUZ54

Coax. Cable

<3

EB

0000

»

n 3 à

Coax. Cable

Monitor

AC 120V 60Hz

CONNECTIONS

CAUTION:

• The following connection should be made by qualified

service personnel or system installers.

• Make all connections with the power turned OFF.
• Avoid shorting the terminals, as this may blow a fuse.

If the installation is to be upside-down, the Pan Left-Right
and Tilt Up-Down directions will be reversed. This must be
considered when the wiring is done.
In this case, replace 1 and 2 pins of CN1 and CN2.
If the Pre-wired Cable WV-CA50 is used, replace them using
with MOLEX brand tool 57031-6000.

A. Wiring for Pan/Tllt and Motorized Zoom, Focus, Iris

Control

Control Voltage

Control Current

ZOOM

TELE

-6VDC

WIDE

-F6V DC

FOCUS NEAR

-6VDC

Less than 100 mA

FAR

-fe v o c

IRIS

OPEN

-6VDC

CLOSE

-fe v D C

B. The Video and Exit Sync. Terminal Board.

1. Wiring precautions:

• Do not bend coaxial cable into a curve who radius

is smaller than 10 times diameter.

• Never staple the cable - not even with circuì

staples.

• Never crush or pinch the cable.

All these will change the impedance of the cable and cause

poor picture quality.

2. Use the following conditions Cable.

Impedance: 75fì
Diameter: S mm or less
Example: RG - 59/U (BELDEN 9259}

3. Wiring:

• Prepare coaxial cable as shown as below.

Fold back

• Connect as follows.

1 Clamp the coaxial cable with Cable Clamp.

2 Fold back the shield
3 Connect the inner conductor.

When using a camera with motorized zoom, focus and
iris, these connections should be made.

Note:

Lens control cable should be approx. 39'
to allow sufficient room for PaaTilt.

-

6

-