beautypg.com

ITW Linx DL1200-CAT5 User Manual

ITW Linx Routers

background image

DATALINX 1200-CAT5 FEATURES

Protects 12 8-wire (4-pair) ports – Solid-state, Primary protection,

UL 497.

RJ45 input/output.

Single height chassis (1U).

Replaceable 4-port modules – In the event of a catastrophic surge you

will not need to replace the entire unit, just the modules that have been
effected.

TROUBLESHOOTING
1. INTERMITTENT OR NO CONNECTION SIGNAL.

Check integrity of the patchcord. Visually inspect for any lose or

non-connected wires. Verity that wires are connected in compliance

with either TIA 568-A or 568-B standards.

NOTE: If system-operating voltage exceeds the listed clamping voltage

for your unit or if a surge is present on the network, the port will

be connected to GND by design. Remove surge source or check

the system voltage.

If you continue to have trouble with your DataLinx 1200-T1A or

this section has not fixed the problem, please call ITW Linx

Customer Service at: 1-800-336-LINX (5469).

CAUTION:

1. Never install telephone wiring during a lightning storm.

2. Disconnect telephone lines before installing protector.

3. Protector and equipment ground should be connected to a single

common ground.

4. Make sure no electrical surges are on the lines when installing or

removing circuit cards.

5. The protector shall be installed in accordance with the applicable

requirements of the National Electric Code, ANSI/NFPA-70, Article 800,

Section C.

NOTE:

1. Many old buildings are inadequately wired. It is very common for a

building to be improperly grounded. Building wiring and grounding

must conform to applicable NEC (USA) or CEC (Canada). Ground

impedance for primary applications are recommended to be 1 ohm

or less. Protectors will not function properly when connected

improperly or to a faulty ground.

2. The DataLinx 1200-CAT5 and the connected equipment must be

indoors and in the same building.

Front View

Rear View

DL1200-CAT5 INSTALLATION INSTRUCTIONS

Model: DL1200-CAT5 (16V), DL1200-CAT5 (75V/POE), DL1200-CAT5 (235V)

DATALINX REPLACEMENT CARD INSTALLATION INSTRUCTIONS -

DL1200-RC-CAT5 (16V, 75/POE, 235V)

1. Remove all plugs from the jacks in the protector.
2. Remove (7) screws.
3. Remove cover.
4. Remove (2) screws on module.
5. Remove module and insert new module.
6. Attach (2) screws on module.
7. Replace cover and fasten with (7) screws.
8. Insert plugs into proper jack locations.

CAUTION:
1. Never install telephone wiring during a lightning storm.
2. Disconnect telephone lines before installing protector.
3. Protector and equipment ground should be connected to a single

common ground.

4. Make sure no electrical surges are on the lines when installing or

removing circuit cards.

5. The protector shall be installed in accordance with the applicable

requirements of the National Electric Code, ANSI/NFPA-70, Article 800,

Section C.

DL1200-CAT5

1

2

3

4

5

6

7

8

9

10

11

12

12

11

10

9

8

7

6

5

4

3

2

1

For Technical Support, Please Contact Us at 1.800.336.5469

www.itwlinx.com • 425 North Gary Ave., Carol Stream, IL 60188

Part#: 2500-650-30I REV 3 (09/2010)

PATENTED: 6134093