beautypg.com

Pridiom Landmark Series Installation Manual User Manual

Page 12

background image

11

*

Connection of power cable

*

INSTALLATION & REPAIR GUIDE

Split Wall-Mounted air conditioner

1.Remove the drawer of the outdoor unit.

2.Connect the indoor power and control

wires with the matched outdoor wires in accordance

with the electric schematic diagram and make sure

that the connection is firmly done(Fig.7)

wire pressing plate

Drawer screw

3.Use a press plate to fix the wires firmly,and re-install

the drawer.

Note:Do not connect the wires in a wrong way,otherwise electric malfunctions will be caused and

even damages to the units will occur.The appliance shall be installed in accordance with national

wiring regulation.If the supply cord is damaged,it must be replaced by the manufacturer or its service

agent or a similarly qualified person in order to avoid a hazard.The plug shall be accessible after

installing the appliance.If the model have not plug that a switch which have a contact separation

of at least 3 mm(1/10") in all poles shalled be added in fixed wiring.

*

Use thermal tube to wrap the joints and wrap the tube tightly with ethylene tapes.

*

Fix the wrapped pipelines on the exterior wall with clamps.

*

Fill in the gaps left over by the pipeline hole and wall hole to prevent rain-water from entering.

*

Finishing touches

*

*

Connect to the power source,check if the function selection keys on the remote controller are

working properly.
*

Check if the room temperature adjustments and timer settings are working properly.

*

Check if the drain is smooth.

*

Check if there is any abnormal noise or vibration during operation.

*

Check if there is leakage of refrigerant.

*

Test running

*

Fig.7

*

Is the unit installed correctly?

*

*

Isn't there anything which prevents ventilation or obstructs operation in front of the indoor unit ?

Do not install the unit following place .
*

Inflammable gases may leak .

*

Oil splashes a lot .

*

In case where the unit is used in such places as poisonous or sultry gases are generated or seaside

district exposed to sea breezes corrosion may cause malfunction . Consult with your distributor .
*

Air conditioner body and remote controller must be I m(39-3/4") or more away from a TV or a radio.

Drain the dehumidified water from the indoor unit to a place which drains well .

*

When installing the unit , choose a place which can stand the weight of the unit well and does

not increase the operation noise or vibration . Especially where there is a possibility that vibration

be transmitted to the house , fix the unit by inserting attached vibration -proof pads between the

unit and fittings .

*Suitable Installation Position

*Pay attention to operation noise