7. After the engine starts, warm up the engine until
the engine does not stop when the choke knob is
returned to the original position.
TIP
When starting the engine, with the economy control
switch “ON”, and there is no load on the generator:
9 in ambient temperature below 0°C (32°F), the
engine will run at the rated r/min (4,500 r/min) for 5
minutes to warm up the engine.
9 in ambient temperature below 5°C (41°F), the
engine will run at the 4,500 r/min for 3 minutes to
warm up the engine.
The economy control unit operates normally after the
above time period, while the economy control switch is
“ON”.
5. Pull the choke knob 1 fully out.
1 Choke knob
TIP
The choke is not required to start a warm engine.
Push the choke knob in to the original position.
6. Pull slowly on the recoil starter until it is engaged,
then pull it briskly.
TIP
Grasp the carrying handle firmly to prevent the genera-
tor from falling over when pulling the recoil starter.
7DK-042
7DK-041
1
7DK-040
1
7DK-039
4. Turn the engine switch (Red) to “ON” 1.
1
7 “ON”