Core removal, Rim and mortise cylinders bored locks, Inserting cylinder core – SARGENT 7800 Knob Locks User Manual
Page 2
CORE REMOVAL
6300 and 10-6300 cores keyed 1 bitted use a control key cut 113511
RIM AND MORTISE CYLINDERS
LEVER BORED LOCKS
Insert control key and turn
counterclockwise until stop
is reached.
With key in this position, pull out core.
To remove key — return to vertical
position and withdraw.
Insert control key and rotate 15 degrees
counterclockwise
With key in this position, pull out core.
RIM AND MORTISE CYLINDERS
BORED LOCKS
To remove key, return
to vertical position and
withdraw. (Note: for easiest
key removal hold core
in place while starting to
withdraw key.)
Install 6 pin tail piece in back of core when
used in lever/bored locks
Insert control key and rotate 15
degrees counterclockwise.
Insert core into lock and turn
key clock wise until it stops and
remove key
INSTRUCTIONS FOR THE REMOVAL AND INSERTION OF
SARGENT 6300 and 10-6300 REMOVABLE CORE CYLINDERS
For assistance, contact SARGENT at 800-727-5477 or www.sargentlock.com
A5634L
C
C
New Cylinder
C
New Cylinder
To remove 60- plastic disposable core pull from lock, save and reuse tail piece in permanent core on bored locks
Copyright © SARGENT Manufacturing. All rights reserved. Reproduction in whole or in part without the express
written permission of SARGENT Manufacturing is prohibited.
INSERTING CYLINDER CORE
Make sure that key
clearance slot faces
down.
With pins aligned in housing as shown below, with
control key in core rotate key counter clock wise
and insert core in to housing.
15°
Note: pins should be
positioned at about a
15° angle to align with
holes in core.
To remove key, return to
vertical position and withdraw.
(Note: for easiest key removal
hold core in place while
starting to withdraw key.)
REMOVING CORE FROM BORED LOCKS
INSTALLING CORES IN BORED LOCKS
6, 8 And 9 line locksets should be
assembled and have outside knobs
locked (by inside knob push or turn
button — or by inside knob key).
Then insert control key and turn
counterclockwise until stop is reached.
With key in this position, pull out core.
To remove key — return to vertical
position and withdraw.
6, 8 And 9 line locks should be assembled and have
outside knobs locked (by inside knob push or turn button
— or previously by outside knob, key or construction
plug). Then insert control key into replacement core and
turn counterclockwise until stop is reached. Slide core
onto pins and into knob.
Note: if inside
knob button will
not lock knob,
rotate pins in
knob 180°.
Note
: pins in knob should be positioned at
about a 15° angle to align with holes in core.
15°