Page 43

Page 43
MODEL 2900s - Downflow
Hard water enters unit at valve inlet — flows up into
injector housing and down thru nozzle and orifice —
around the piston — down thru mineral — enters center
tube thru bottom distributor — flows up thru center tube
— around piston and out thru the drain line.
Hard water flows thru the regenerating valve directly down thru the
mineral into the bottom distributor and up thru the center tube — around
the piston and out the drain line.
6
BRINE TANK FILL POSITION
Hard water flows thru the service valve and down thru the mineral.
Conditioned water enters the bottom distributor — flows up the center
tube around the piston to the outlet. Hard water flows to the
regenerating valve thru the injector housing and brine valve to fill the
brine tank.
5
RAPID RINSE
4
SLOW RINSE POSITION