Glass fiber installation, Plastic fiber installation, Specifications – Banner MINI-BEAM Expert Series User Manual
Page 4
1. Connect the sensor’s gray wire.
2. Four-pulse the remote line to enable or disable the push button.
The sensor toggles between enable and disable settings and returns to RUN mode.
Glass Fiber Installation
O-ring
Retaining Clip
1. Install the O-ring (supplied with the fiber) on each fiber end, as shown in the drawing.
2. While pressing the fiber ends firmly into the ports on the sensor front, slide the U-shaped retaining clip (supplied with the sensor) into the slot in the sensor’s barrel,
until it snaps into place.
Plastic Fiber Installation
Trimmed fiber
control ends
Plastic fiber
emitter port
Plastic fiber
receiver port
Gripper
Unlock
Lock
Adapters for
0.25- and 0.5-mm fibers
Sensor Face
1. With supplied fiber cutter, make a clean cut at control ends of fibers.
2. Unlock the fiber gripper as shown below. Apply appropriate fiber adaptors prior to fiber insertion, if needed.
3. Gently insert the prepared fiber ends into the ports, as far as they will go.
4. Slide the fiber gripper back to lock, as shown below.
Specifications
General
Outputs
Supply Voltage and Current
10 to 30V dc (10% maximum ripple) at less than 45 mA, exclusive of
load
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Adjustments
Push-button TEACH mode sensitivity setting; remote TEACH mode input
is provided
Indicators
Two LEDs: yellow and bi-color green/red
Construction
Reinforced thermoplastic polyester housing, totally encapsulated, o-ring
seal, acrylic lenses, and stainless steel screws.
Connections
Output Configuration
Bipolar: One current sourcing (PNP) and one current sinking (NPN)
open-collector transistor
Output Rating
150 mA maximum each output at 25° C, derated to 100 mA at 70° C
(derate ≈1 mA per °C)
Off-state leakage current: less than 5 μA at 30V dc
ON-state saturation current: less than 1V at 10 mA; less than 1.5V at
150 mA
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or
short-circuit of outputs
Output Response Time
MINI-BEAM Expert Series Installation Guide
4
www.bannerengineering.com - tel: 763-544-3164
P/N 068812 Rev. B