beautypg.com

Glass fiber installation, Plastic fiber installation, Specifications – Banner MINI-BEAM Expert Series User Manual

Page 4

background image

1. Connect the sensor’s gray wire.
2. Four-pulse the remote line to enable or disable the push button.

The sensor toggles between enable and disable settings and returns to RUN mode.

Glass Fiber Installation

O-ring

Retaining Clip

1. Install the O-ring (supplied with the fiber) on each fiber end, as shown in the drawing.
2. While pressing the fiber ends firmly into the ports on the sensor front, slide the U-shaped retaining clip (supplied with the sensor) into the slot in the sensor’s barrel,

until it snaps into place.

Plastic Fiber Installation

Trimmed fiber
control ends

Plastic fiber

emitter port

Plastic fiber
receiver port

Gripper
Unlock

Lock

Adapters for
0.25- and 0.5-mm fibers

Sensor Face

1. With supplied fiber cutter, make a clean cut at control ends of fibers.
2. Unlock the fiber gripper as shown below. Apply appropriate fiber adaptors prior to fiber insertion, if needed.
3. Gently insert the prepared fiber ends into the ports, as far as they will go.
4. Slide the fiber gripper back to lock, as shown below.

Specifications

General

Outputs

Supply Voltage and Current

10 to 30V dc (10% maximum ripple) at less than 45 mA, exclusive of
load

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Adjustments

Push-button TEACH mode sensitivity setting; remote TEACH mode input
is provided

Indicators

Two LEDs: yellow and bi-color green/red

Construction

Reinforced thermoplastic polyester housing, totally encapsulated, o-ring
seal, acrylic lenses, and stainless steel screws.

Connections

Output Configuration

Bipolar: One current sourcing (PNP) and one current sinking (NPN)
open-collector transistor

Output Rating

150 mA maximum each output at 25° C, derated to 100 mA at 70° C
(derate ≈1 mA per °C)
Off-state leakage current: less than 5 μA at 30V dc
ON-state saturation current: less than 1V at 10 mA; less than 1.5V at
150 mA

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or
short-circuit of outputs

Output Response Time

MINI-BEAM Expert Series Installation Guide

4

www.bannerengineering.com - tel: 763-544-3164

P/N 068812 Rev. B

This manual is related to the following products: