3 control panel, Control panel, System overview – Barco R9855510 User Manual
Page 20
2. System Overview
2.5.3
Control panel
Description
Image 2-9
Control panel
The control panel of the EPS8DE consists of:
•
Starting key (off / on / glow / start)
•
Pilot lamp green (contact on / off), lamp lights up when contact on
•
Pilot lamp red (charging current battery), lamp lights up when battery is not being charged
•
Hours counter
•
1 fuse ( 2A ) hours counter
•
Measuring unit , 3-fases for voltage, frequency en current
•
Voltage presence indicator ( 3-fases )
•
3 fuses ( 2 A ) for mentioned above
•
Main breaker 25A 4p
•
Earth leakage protection 40A 4p,300mA, class A
•
1 x breaker 16A 2p/C/10kA (electronics)
•
1 x breaker 16A 2p/C/10kA (hydraulics )
•
1 x breaker 10A 2p/C/10kA (lights)
•
4 x breaker 16A 2p/C/10kA (video screen)
•
1 x socket CE 16 (electronics)
•
1 x socket CE 16 (hydraulics)
•
1 x socket CE 16 (lights)
•
1 x Tour mate multiconnector female chassis ( supply video )
•
Earth connection point
•
Emergency stop
•
32A CEE free socket (power from generator set)
•
32A CEE plug panel mount (supply to power distribution box) possibility to provide power from auxiliary device (grid)
16
R5976956 B-10 MOBILE LED 19/06/2007