a) For Channel, select the channels whose signals are to be monitored. The first Channel selection plots

on the vertical axis; the second Channel selection plots on the horizontal axis.

b) For Signal, select the signals you want to monitor.

c) For Plot Mode, select X/Y Plot.

3. Customize the plot as required:

In the toolbar, click the Setup Scope icon to set up the scope display as desired using the Graph and
Trace tab controls.

Units/div–specifies the grid line values.

Offset–specifies how much the grid’s zero reference on the Y axis shifts from the center of the display.

Trace Time–Specifies the length of time for a signal trace to cross the scope (also sets the grid’s X
axis scale). You can jog the values up and down with the up-down control.

MTS Series 793 Control Software 407

Scopes and Meters