English, Electrical specifications, Symbols used on lcd – Klein Tools CL3200 User Manual
Page 6

ENGLISH
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
1.0V ~ 1000V
0.001V ~ 1V
± (1.0% + 4 digits)
-1.0V ~ -1000V
0.001V ~ 1V
Overload Protection:
1000V
Input Impedance (Nominal): >10MΩ, < 100pF
AC Voltage Measurement
Range
Resolution
Accuracy
1.2V ˜ 750V
0.001 ~ 1V
± (1.5% + 3 digits)
Overload Protection:
750V RMS
Frequency Response:
45 to 400 Hz
Response:
Averaging
Input Impedance (Nominal): >10MΩ, < 100pF
Input Impedance (Low Z) >3kΩ, <200pF, up to 600V RMS
AC Current Measurement
Range
Resolution
Accuracy
0.9A ~ 200A
0.1A
± (2.0% + 8 digits)
Overload Protection:
• Current:
200A
Frequency:
45 to 1kHz
Response:
Averaging
Resistance Measurement
Range
Resolution
Accuracy
400
Ω ˜ 4MΩ
0.1
Ω ˜ 0.001MΩ
± (1.0% + 4 digits)
40M
Ω
0.01M
Ω
± (2.0% + 4 digits)
Overload Protection:
600V RMS
Continuity Test
Overload Protection
Open Circuit Voltage
Threshold (Appx.)
600V RMS
< 0.44V
< 40
Ω
Overload Protection:
600V RMS
Non Contact Voltage Detector
On Voltage
Appx. 25V AC and above
SYMBOLS USED ON LCD
~
AC Measurement
DC Measurement
-
Negative DC Value
AT
Auto Range Active
O.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in Ohms
Continuity Test
k
Kilo 10
3
M
Mega 10
6