Dickson PR125 User Manual
Pr125, Pressure data logger
PR125
Phone: 1-800-757-3747 | Fax: 1-800-676-0498 | Email: [email protected] | For calls outside the US please call: 1-630-543-3747
_________________________________________________________________________________________________
Pressure Data Logger
_________________________________________________________________________________________________
Specifications
Ambient Operating RH Conditions : 0 to 100% RH
Ambient Operating Temperature Conditions: -4 to 158F (-20 to 70C)
Approvals: RoHS, CE
Battery Life (Avg): 6 Months (at 5 Minute Sample Rate)
Cable Details: USB - Male Series A plug to 5 pin Male Series B mini plug.
Cable Length: 6ft
Calibration Options: N100, N300
Data Capacity: 64,768
Delayed Start: Yes
Display Dimensions Height: 0.56
Display Dimensions Width: 0.8
Display Resolution: Depends on Unit of Measure Selected from 0.000 to 0000; 0.1PSI
Display Type: LCD
Display Update Rate: 20 Seconds
Download Time: 45 Seconds
Download Type: USB / Flash Card
Enclosure: Glass Filled Polycarbonate; Stainless Steel Hex
Fitting: 1/4" NPT Thread; 1.11" Hex (Sensor includes built in Diaphragm Seal)
IP Rating: 68
Included Accessories: One DL123 Lithium Battery and Quick Start Guide. *Software sold separately.
Minimum Software Version Required: 12.4
Mounting Options: Stem
PC Requirements: MS Windows 98 or newer
Power Source: Battery; DL123 Lithium Battery (User Replaceable)
Power Status Indicator: LCD Display
Pressure Accuracy: 1%
Pressure Range: 0 to 100PSI
Sample Interval: User Selectable (From 1 second to 24 hours).
Unit Weight: 3 lbs
Units of Measure: PSI, ATM, Bar, mBar, InH2O, FtH2O, mmH2O, mmHG, InHg, Pascal, kP, MCA
Units/Pkg: 1
Warranty: 12-Month Limited