Agilent Technologies E3632A User Manual
Page 77

Chapter 4 Remote Interface Reference
SCPI Command Summary
74
APPLy {
current
>|DEF|MIN|MAX}]
APPLy?
[SOURce:]
 CURRent[:LEVel][:IMMediate][:AMPLitude]{
|MIN|MAX|UP|DOWN}
 CURRent[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX]
 CURRent[:LEVel][:IMMediate]:STEP[:INCRement] 
 {
 CURRent[:LEVel][:IMMediate]:STEP[:INCRement]? {DEFault}
 CURRent[:LEVel]:TRIGgered[:AMPLitude] {
 CURRent[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX]
 CURRent:PROTection[:LEVel] {
 CURRent:PROTection[:LEVel]? {MIN|MAX}
 CURRent:PROTection:STATe {0|1|OFF|ON}
 CURRent:PROTection:STATe?
 CURRent:PROTection:TRIPped?
 CURRent:PROTection:CLEar
 VOLTage[:LEVel][:IMMediate][:AMPLitude]{
 VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX]
 VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]
 {
 VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]? {DEFault}
 VOLTage[:LEVel]:TRIGgered[:AMPLitude] {
 VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX]
 VOLTage:PROTection[:LEVel] {
 VOLTage:PROTection[:LEVel]? {MIN|MAX}
 VOLTage:PROTection:STATe {0|1|OFF|ON}
 VOLTage:PROTection:STATe?
 VOLTage:PROTection:TRIPped?
 VOLTage:PROTection:CLEar
 VOLTage:RANGe {P15V|P30V|LOW|HIGH}
 VOLTage:RANGe?
MEASure
 :CURRent[:DC]?
[:VOLTage][:DC]?
Output Setting and Measurement Commands