Using Your Universal Room Controller

8

Figure 6: Example of a Typical RC-8RK / RC-8RKL Configuration

Table 6: Connection Scheme (for the example in Figure 6)

This connector:

Controls:

RELAY2

The lights

RELAY1

The screen

RS-485

Terminal Block Connector

A power amplifier (and speakers)

RS-232

(

TX1

,

RX1

) Terminal Block Connector

A projector

1

IR OUT1

PIN

2

A DVD player

IR OUT2

PIN

2

A video player

1 The second RS-232 port can be used to control another A/V unit or an LCD
2 Connected via the IR emitter cable. IR OUT1 and IR OUT2 can each be connected to identical machines and still be
controlled separately